Power
Switchgear, UPS, generators and transfer switches keep the power on and meter energy. 79 device types.
-48 V DC power plant
Powers telecom and protection on DC; rectifier modules and batteries back each other up.
Protocols: Modbus TCP · SNMP v3
Used in: Semiconductor & IC manufacturing · Data centers · Copper tube & metal processing
12 / 18-pulse front end
Multi-pulse rectifiers cancel harmonics through a phase-shifting transformer; an unbalanced leg shows as rising THD.
Protocols: Modbus TCP · EtherNet/IP
Used in: Copper tube & metal processing · Glass manufacturing
5 brands: ABB, Hiconics, Inovance, Rockwell Automation, Toshiba
Active front end (AFE) drive
An IGBT rectifier draws near-sinusoidal current and can regenerate to the grid.
Protocols: Modbus TCP · OPC UA · EtherNet/IP
Used in: General & discrete manufacturing · Copper tube & metal processing
6 brands: ABB, Danfoss, Inovance, Rockwell Automation, Siemens, Yaskawa
Active harmonic filter (APF)
Injects opposing harmonic current to cancel the load's harmonics, and can also correct reactive power and imbalance. THDi before and after shows the effect.
Protocols: Modbus TCP · OPC UA · Modbus RTU
Used in: Semiconductor & IC manufacturing · Electronics & flat-panel display · Data centers · General & discrete manufacturing · Copper tube & metal processing
23 brands: ABB, Acrel, CEEG, Chint, Circutor, Comsys, Danfoss, EAST, Eaton, Inpower, Kehua, Merus Power, MTE Corporation, Omniverter, Schneider Electric, Siemens, Sinexcel, Socomec, TCI, Windsun, YADA, Yisen, Zhuiri
Arc-flash protection relay
Detects arc light and trips in milliseconds. A protection device: always read-only.
Protocols: IEC 61850 · Modbus TCP · DNP3 · IEC 104
Used in: Semiconductor & IC manufacturing · Data centers · Copper tube & metal processing
5 brands: ABB, Eaton, Schneider Electric, SEL, XJ Electric
Area energy meter
Meters power and demand per workshop or system for energy analysis and cost allocation. Read-only.
Protocols: Modbus TCP · BACnet/IP · Modbus RTU · DL/T 645 · M-Bus · DNP3 · IEC 61850
Used in: Semiconductor & IC manufacturing · Electronics & flat-panel display · New-energy manufacturing · Biopharma & life sciences · General & discrete manufacturing · Copper tube & metal processing · Glass manufacturing
27 brands: ABB, ABB China, Accuenergy, Acrel, Camille Bauer, Carlo Gavazzi, Chint, Circutor, Continental Control Systems, Delixi, DENT Instruments, Eastron, Electro Industries/GaugeTech, Elspec, Finder, Gossen Metrawatt, Iskra, Janitza, Leviton, Lovato Electric, SATEC, Schneider Electric, Sfere, Siemens, Socomec, Veris, YADA
Automatic capacitor bank
Switches capacitor steps automatically on power factor (often detuned against resonance). The controller switches steps; the platform never does.
Protocols: Modbus TCP · OPC UA · IEC 61850 · DNP3 · IEC 104 · Modbus RTU
Used in: Semiconductor & IC manufacturing · General & discrete manufacturing · Copper tube & metal processing · Glass manufacturing · Logistics & warehousing · Commercial buildings
13 brands: Acrel, Arteche, Chint, Circutor, Delixi, Eaton, GE Vernova, Siemens, Sieyuan, Socomec, TDK Electronics, XJ Electric, Yisen
Battery cell monitoring
Measures every cell's voltage, resistance and temperature to find the bad cell before it fails a UPS discharge.
Protocols: Modbus TCP · SNMP v3 · Modbus RTU
Used in: Semiconductor & IC manufacturing · Data centers · Healthcare
5 brands: BTECH, GENEREX, Jiehua, NDSL Cellwatch, Vertiv Albér
Battery room
UPS batteries last longest near 77°F; every 15°F hotter roughly halves their life.
Protocols: Modbus TCP · SNMP v3 · Modbus RTU
Used in: Data centers
5 brands: AKCP, BTECH, Nexceris, Shuangdeng, Vertiv Albér
Branch transfer switch
Moves its branch of load to the generator when the utility fails. Hospitals split life-safety, critical and equipment branches (NFPA 99/110); the switch transfers on its own.
Protocols: Modbus TCP · Modbus RTU
Used in: Biopharma & life sciences · Healthcare
10 brands: ABB, ASCO, Chint, CNC, Liangxin, Russelectric, Schneider Wangao, Socomec, TENGEN, Zenith
Building main meter
Whole-building power and power per square foot (energy intensity). Read-only.
Protocols: Modbus TCP · BACnet/IP · SNMP v3 · Modbus RTU · DL/T 645 · DNP3 · IEC 61850 · M-Bus
Used in: Commercial buildings
18 brands: ABB China, Accuenergy, Acrel, Camille Bauer, Circutor, Continental Control Systems, Eastron, Eaton, Electro Industries/GaugeTech, Elspec, Finder, Gossen Metrawatt, Iskra, Janitza, Leviton, Lovato Electric, SATEC, Schneider Electric
Bushing monitor
Tracks bushing power factor and capacitance; bushing failure is a common cause of transformer fires.
Protocols: IEC 61850 · DNP3 · Modbus TCP
Used in: Semiconductor & IC manufacturing · Copper tube & metal processing
6 brands: Camlin Energy, Doble Engineering, Hitachi Energy, OMICRON, Qualitrol, Zhongfen
Busway / cable temperature (DTS)
Fibre distributed or joint temperature sensing catches overloads and loose joints early.
Protocols: Modbus TCP · IEC 61850
Used in: Semiconductor & IC manufacturing · Data centers · Copper tube & metal processing
5 brands: AP Sensing, Bandweaver, Cementys, Exertherm, Luna Innovations
Diesel fuel system
Bulk tanks, day tanks, transfer pumps and polishing; fuel decides how long an outage can be ridden out.
Protocols: Modbus TCP · BACnet/IP · Modbus RTU
Used in: Data centers · Healthcare
4 brands: Jiechuang, Preferred Utilities, Simplex, Veeder-Root
Disturbance recorder
Records voltages and currents at 64–256 samples per cycle when a fault happens (COMTRADE files), to analyse the fault type and whether protection operated correctly. Read-only.
Protocols: IEC 61850 · DNP3 · Modbus TCP
3 brands: Doble Engineering, Qualitrol, SEL
dv/dt filter
Limits the drive's voltage rise rate to ease motor insulation stress.
Protocols: Modbus TCP · EtherNet/IP · Modbus RTU
Used in: General & discrete manufacturing
5 brands: ABB, Danfoss, INVT, MTE Corporation, Schaffner
Dynamic voltage restorer (DVR)
Injects the missing voltage within milliseconds during a sag to protect sensitive lines.
Protocols: Modbus TCP · IEC 61850 · Modbus RTU · IEC 104
Used in: Semiconductor & IC manufacturing · Electronics & flat-panel display · New-energy manufacturing
8 brands: ABB, Arteche, Inpower, Kehua, Measurlogic, Omniverter, SEARI, Sifang
EMI filter
Suppresses conducted interference; rising leakage current means ageing capacitors.
Protocols: Modbus TCP · Modbus RTU
Used in: Semiconductor & IC manufacturing · Healthcare
3 brands: INVT, Schaffner, TDK Electronics
EV chargers
Employee and fleet EV chargers. Their load adds to the site demand peak and can be shifted.
Protocols: Modbus TCP · MQTT
Used in: General & discrete manufacturing · Logistics & warehousing · Commercial buildings
7 brands: ABB E-mobility, ChargePoint, Schneider Electric, Star Charge, TELD, Wallbox, XJ EV
Fixed capacitor bank
Capacitors fixed on a motor or bus; watch current, temperature and fuses.
Protocols: Modbus TCP · DNP3 · Modbus RTU
Used in: General & discrete manufacturing · Copper tube & metal processing
4 brands: Chint, Eaton, GE Vernova, TDK Electronics
Flywheel / rotary UPS
A flywheel carries the load for seconds until the generator starts; its speed is the stored energy. Monitored only.
Protocols: Modbus TCP · SNMP v3
Used in: Semiconductor & IC manufacturing · Data centers
4 brands: Hitec Power Protection, Piller, Qifeng, VYCON
Forklift charging room
Forklift batteries charge between shifts. Lead-acid charging releases hydrogen, so the room needs exhaust and H2 detection.
Protocols: Modbus TCP · Modbus RTU
Used in: Logistics & warehousing
Fuel cell
Natural-gas or hydrogen fuel cells, for base load or backup.
Protocols: Modbus TCP
Used in: Data centers · Commercial buildings
4 brands: Bloom Energy, Doosan Fuel Cell, FuelCell Energy, REFIRE
Generator
When the utility fails the generator starts and takes the emergency load within 10 seconds. It waits on standby and is load-tested monthly. The platform monitors only — it never starts or stops it remotely.
Protocols: Modbus TCP · Modbus RTU · SNMP v3
Used in: Semiconductor & IC manufacturing · Electronics & flat-panel display · New-energy manufacturing · Biopharma & life sciences · Data centers · General & discrete manufacturing · Glass manufacturing · Logistics & warehousing · Commercial buildings · Healthcare
12 brands: Bernini Design, Caterpillar, ComAp, Cummins, Deep Sea Electronics, Generac, Kohler, MTU, Perkins, SmartGen, Volvo Penta, Woodward
Generator paralleling switchgear
Synchronizes generators onto a common bus and adds or sheds sets with load. Monitored only.
Protocols: Modbus TCP · Modbus RTU
Used in: Data centers · Healthcare
4 brands: ASCO, Russelectric, SmartGen, Woodward
Hospital main meter
The hospital's main service power. Read-only.
Protocols: BACnet/IP · Modbus TCP · IEC 61850 · DNP3
Used in: Healthcare
2 brands: Schneider Electric, SEL
Hybrid harmonic filter
A passive branch takes the bulk of harmonics and vars; an active part cleans up the rest at lower cost.
Protocols: Modbus TCP · Modbus RTU
Used in: General & discrete manufacturing · Copper tube & metal processing
3 brands: Circutor, Schneider Electric, Sinexcel
Insulation monitoring device (IT system)
An ungrounded (IT) system keeps running after a first ground fault, which must be found and fixed fast.
Protocols: Modbus TCP · BACnet/IP · Modbus RTU
Used in: Semiconductor & IC manufacturing · New-energy manufacturing · Healthcare
3 brands: Acrel, Bender, Schneider Electric
Isolated power panel (LIM)
The OR's isolated power; the line isolation monitor alarms when total hazard current exceeds 5 mA (NFPA 99).
Protocols: Modbus TCP · BACnet/IP · Modbus RTU
Used in: Healthcare
4 brands: Acrel, Bender, Post Glover, Schneider Electric
Isolation / K-rated transformer
Isolates noise and carries harmonic-rich loads (K-rated); winding temperature shows harmonic heating.
Protocols: Modbus TCP · SNMP v3 · Modbus RTU
Used in: Data centers · Healthcare
7 brands: Controlled Power Company, Hammond Power Solutions, Huapeng, Mirus International, Onelec, POWERVAR, Schneider Electric
Line / DC-link reactor
In a drive's input or DC link, reducing harmonics and surges.
Protocols: Modbus TCP · EtherNet/IP · Modbus RTU
Used in: General & discrete manufacturing · Copper tube & metal processing
6 brands: ABB, Hammond Power Solutions, Inovance, INVT, MTE Corporation, TCI
Load bank
Tests generators and UPS under load; watch the applied power and temperature.
Protocols: Modbus TCP · Modbus RTU
Used in: Data centers · Healthcare
4 brands: Avtron Power Solutions, Crestchic, Hengtai, Simplex
Low-voltage switchgear
The 480 V distribution feeding tools, air handlers and utility equipment.
Protocols: IEC 61850 · Modbus TCP · BACnet/IP · Modbus RTU
Used in: Semiconductor & IC manufacturing · Electronics & flat-panel display · New-energy manufacturing · Biopharma & life sciences · Data centers · Copper tube & metal processing · Glass manufacturing · Healthcare
6 brands: ABB, Chint, Daqo Group, Eaton, Schneider Electric, Siemens
Main service meter
Total site power and the solar share. Read-only.
Protocols: BACnet/IP · Modbus TCP · DNP3 · IEC 61850
Used in: Logistics & warehousing
2 brands: Schneider Electric, SEL
Main switchgear meter
The plant's main service meter: power, demand and power factor. Energy per part is computed from it. Read-only.
Protocols: Modbus TCP · BACnet/IP · IEC 61850 · SNMP v3 · Modbus RTU · DL/T 645 · DNP3 · M-Bus
Used in: General & discrete manufacturing
19 brands: ABB China, Acrel, Camille Bauer, Circutor, Continental Control Systems, Eastron, Eaton, Electro Industries/GaugeTech, Elspec, Finder, Gossen Metrawatt, Iskra, Janitza, Leviton, Lovato Electric, SATEC, Schneider Electric, Siemens, Socomec
Medium-voltage switchgear
Utility 13.8 kV incoming and feeder breakers with protective relays. A trip drops a whole block of load. The platform monitors only — it never opens or closes a breaker.
Protocols: IEC 61850 · Modbus TCP · BACnet/IP · Modbus RTU
Used in: Semiconductor & IC manufacturing · Electronics & flat-panel display · New-energy manufacturing · Biopharma & life sciences · Data centers · Copper tube & metal processing · Glass manufacturing
7 brands: ABB, Chint, Daqo Group, Eaton, Schneider Electric, Siemens, TBEA
Microgrid controller
Coordinates PV, storage, generators and the utility, including island/grid transitions. Read-only.
Protocols: Modbus TCP · OPC UA · DNP3 · IEC 61850 · IEC 104
Used in: New-energy manufacturing · General & discrete manufacturing · Commercial buildings
4 brands: Hitachi Energy, NARI, Schneider Electric, SEL
Motor control center
Feeds the production motors. Power factor and harmonics affect the power bill and equipment life.
Protocols: IEC 61850 · Modbus TCP · BACnet/IP · EtherNet/IP · Modbus RTU
Used in: New-energy manufacturing · General & discrete manufacturing · Copper tube & metal processing · Glass manufacturing
6 brands: ABB, Chint, Eaton, Rockwell Automation, Schneider Electric, Siemens
Natural gas meter
Natural gas for boilers, oxidizers and regeneration heaters in scfh, converted to BTU/h by heating value. Read-only.
Protocols: Modbus TCP · Modbus RTU · BACnet/IP · M-Bus
Used in: Semiconductor & IC manufacturing · Electronics & flat-panel display · New-energy manufacturing · Biopharma & life sciences · General & discrete manufacturing · Copper tube & metal processing · Glass manufacturing · Commercial buildings · Healthcare
Neutral grounding resistor monitor
In a resistance-grounded system the NGR must be intact or ground faults go unseen.
Protocols: Modbus TCP · DNP3 · Modbus RTU
Used in: Semiconductor & IC manufacturing · Copper tube & metal processing
4 brands: I-Gard, Littelfuse, Post Glover, Zhongdian Lide
On-load tap changer control (OLTC)
Steps taps on voltage automatically. Tap position is read-only, never operated remotely.
Protocols: DNP3 · Modbus TCP · IEC 61850 · IEC 104
Used in: Semiconductor & IC manufacturing · New-energy manufacturing · Copper tube & metal processing
4 brands: Beckwith Electric, Eaton, Huaming, Maschinenfabrik Reinhausen
Overhead busway
Plug-in overhead busway feeding racks. A hot joint means a loose connection.
Protocols: Modbus TCP · BACnet/IP · IEC 61850 · SNMP v3
Used in: Data centers
6 brands: Eaton, Legrand, Schneider Electric, Siemens, Starline, Vertiv
Partial discharge monitor
UHF / TEV / ultrasonic sensing catches insulation decay months ahead.
Protocols: IEC 61850 · DNP3 · Modbus TCP
Used in: Semiconductor & IC manufacturing · Electronics & flat-panel display · Data centers
7 brands: Camlin Energy, Doble Engineering, Huacheng, IPEC, Megger, OMICRON, Qualitrol
Passive (tuned) harmonic filter
Capacitors and reactors tuned to the 5th, 7th… absorb those harmonics and supply vars. Capacitor loss or detuning weakens it and risks resonance.
Protocols: Modbus TCP · IEC 61850 · Modbus RTU
Used in: Semiconductor & IC manufacturing · General & discrete manufacturing · Copper tube & metal processing · Glass manufacturing
10 brands: Acrel, Arteche, CEEG, Circutor, Danfoss, Mirus International, MTE Corporation, Schaffner, TCI, TDK Electronics
PDU
PDUs distribute power to each rack; their readings show actual rack load.
Protocols: Modbus TCP · SNMP v3 · BACnet/IP
Used in: Data centers
7 brands: Clever, Eaton, Raritan, Server Technology, Starline, Vertiv, Vertiv Geist
Phase unbalance compensator
Moves current between phases to cut neutral current and transformer losses.
Protocols: Modbus TCP · Modbus RTU
Used in: General & discrete manufacturing · Commercial buildings
Phase-shifting (harmonic-mitigating) transformer
Phase-shifted windings cancel 5th/7th harmonics, often feeding groups of drives.
Protocols: Modbus TCP · Modbus RTU
Used in: General & discrete manufacturing · Copper tube & metal processing
4 brands: Hammond Power Solutions, Huapeng, Mirus International, Schneider Electric
Power conditioner
Regulates, isolates and filters power for imaging and precision equipment.
Protocols: Modbus TCP · SNMP v3 · Modbus RTU
Used in: Semiconductor & IC manufacturing · Healthcare
7 brands: ABB, Controlled Power Company, Eaton, Onelec, Ortea, POWERVAR, Superior Electric
Power factor controller
The brain of a capacitor bank: measures PF and picks the step to switch.
Protocols: Modbus TCP · Modbus RTU
Used in: General & discrete manufacturing · Logistics & warehousing · Commercial buildings
10 brands: Acrel, Chint, Circutor, Delixi, Janitza, Lovato Electric, Sfere, Socomec, TDK Electronics, YADA
Power monitoring
The power monitoring system measures total facility and IT power and computes PUE (facility power ÷ IT power; closer to 1 is better). It is read-only — the platform never writes to it.
Protocols: OPC UA · Modbus TCP · BACnet/IP
Used in: Data centers
4 brands: Acrel, Eaton, Schneider Electric, Siemens
Power quality analyzer (Class A)
Measures harmonics (to the 50th), unbalance, flicker, sags and swells per IEC 61000-4-30 Class A — the data behind IEEE 519 / EN 50160 compliance reports. Read-only.
Protocols: BACnet/IP · Modbus TCP · IEC 61850 · Modbus RTU · DNP3
9 brands: a.eberle, Camille Bauer, Dranetz, Elspec, Fluke, Gossen Metrawatt, Hioki, Powerside, Schneider Electric
Power quality meter
Records sags, harmonics and frequency. A sag of a few cycles can drop tools or servers. Read-only.
Protocols: Modbus TCP · IEC 61850 · Modbus RTU · DNP3 · BACnet/IP
Used in: Semiconductor & IC manufacturing · Electronics & flat-panel display · New-energy manufacturing · Biopharma & life sciences · Data centers · General & discrete manufacturing · Copper tube & metal processing · Glass manufacturing · Logistics & warehousing · Healthcare
9 brands: a.eberle, Camille Bauer, Dranetz, Elspec, Fluke, Gossen Metrawatt, Hioki, Powerside, SEL
Power transformer
Steps medium voltage down to 480 V. High winding and oil temperatures age it fast; a gas or sudden-pressure alarm means an internal fault that needs action now.
Protocols: IEC 61850 · DNP3 · Modbus TCP · Modbus RTU
Used in: Semiconductor & IC manufacturing · Electronics & flat-panel display · New-energy manufacturing · Biopharma & life sciences · Data centers · Copper tube & metal processing · Glass manufacturing
6 brands: Doble Engineering, Eaton Cooper Power, Hitachi Energy, Qualitrol, SGB-SMIT, TBEA
Protection relay
Digital protection of the medium-voltage service and feeders (overcurrent, instantaneous, ground, breaker failure). Its time stamps tell which breaker tripped first. Read-only: the platform never operates a breaker or changes a setting.
Protocols: IEC 61850 · DNP3 · Modbus TCP · IEC 104 · Modbus RTU
20 brands: ABB, Arcteq, Basler Electric, Beckwith Electric, GE, Guodian Nanzi, IESLab, Ingeteam, NR Electric, Schneider Electric, SEL, Shenzhen Nari, Siemens, Sieyuan, Sifang, Toshiba, Wanlida, Woodward, XJ Electric, ZIV
Rainwater harvesting
Collects rain for flushing and irrigation, with city make-up as backup.
Protocols: Modbus TCP · Modbus RTU · BACnet/IP
Used in: Logistics & warehousing · Commercial buildings
Residual current monitor (RCM)
Watches each circuit's residual current to find insulation decay and N-PE faults, without tripping.
Protocols: Modbus TCP · BACnet/IP · Modbus RTU · DNP3
Used in: Data centers · Commercial buildings · Healthcare
5 brands: Acrel, Bender, Doepke, Littelfuse, Schneider Electric
Ring main unit
Load-break switchgear on the MV ring; the platform reads positions, SF6 pressure and fault indicators and never operates it.
Protocols: Modbus TCP · IEC 61850 · DNP3 · IEC 104
Used in: New-energy manufacturing · Data centers · General & discrete manufacturing · Commercial buildings
4 brands: ABB, Eaton, Schneider Electric, Shuangjie
Rooftop solar inverter
Rooftop solar generates during the day and offsets utility power directly.
Protocols: Modbus TCP
Used in: New-energy manufacturing · General & discrete manufacturing · Logistics & warehousing · Commercial buildings
12 brands: Enphase, Fronius, GoodWe, Growatt, Huawei, Kstar, Sineng, SMA, SOFAR, SolarEdge, Solis, Sungrow
Server BMC (Redfish / IPMI)
Out-of-band server management: power, inlet temperature and PSU state, to check IT load.
Protocols: SNMP v3 · MQTT
Used in: Data centers
5 brands: Dell Technologies, HPE, Inspur, Lenovo, Supermicro
Sine-wave filter
Turns drive output into a near-sine voltage, protecting long cables and old motors.
Protocols: Modbus TCP · EtherNet/IP · Modbus RTU
Used in: General & discrete manufacturing · Copper tube & metal processing
6 brands: ABB, Danfoss, INVT, MTE Corporation, Schaffner, TCI
Site utility meter
Whole-site power, energy and power factor. Read-only.
Protocols: BACnet/IP · Modbus TCP · IEC 61850 · Modbus RTU · DL/T 645 · M-Bus · DNP3
Used in: Semiconductor & IC manufacturing · Electronics & flat-panel display · New-energy manufacturing · Biopharma & life sciences · Copper tube & metal processing · Glass manufacturing
21 brands: Badger Meter, CLOU, Diehl Metering, Goldcard, Haoningda, Hexing, Huizhong, Itron, Kamstrup, Landis+Gyr, Linyang, Neptune Technology, Sanchuan, Sanxing, Schneider Electric, Sensus, Sunrise, Suntront, Viewshine, Wasion, XJ Meter
Static transfer switch
Transfers between two UPS sources in milliseconds so single-corded loads get dual power. It switches on its own; read-only.
Protocols: SNMP v3 · Modbus TCP
Used in: Semiconductor & IC manufacturing · Data centers
Static var compensator (SVC)
Thyristor-controlled reactors with capacitor banks, for big fluctuating loads (arc furnaces, mills).
Protocols: Modbus TCP · IEC 104 · IEC 61850 · DNP3
Used in: Copper tube & metal processing
7 brands: GE Vernova, Hitachi Energy, NARI, RXPE, Siemens Energy, Sieyuan, XJ Electric
Static var generator (SVG / STATCOM)
Power electronics supply leading or lagging vars continuously and fast; can also balance phases and cancel some harmonics.
Protocols: Modbus TCP · Modbus RTU · IEC 104 · IEC 61850
Used in: New-energy manufacturing · Data centers · General & discrete manufacturing · Copper tube & metal processing
20 brands: ABB, Acrel, CEEG, Circutor, Comsys, EAST, Hitachi Energy, Inpower, Kehua, Merus Power, NARI, RXPE, Schneider Electric, Siemens Energy, Sieyuan, Sifang, Sinexcel, Windsun, XJ Electric, Zhuiri
Step voltage regulator
Line voltage regulator stepping taps with load on the MV feeder. Tap position is read-only, never operated remotely.
Protocols: Modbus TCP · IEC 61850 · IEC 104 · DNP3
Used in: New-energy manufacturing · Copper tube & metal processing
6 brands: Arteche, Beckwith Electric, Eaton, GE Vernova, NARI, Siemens
Surge arrester monitor
Tracks arrester leakage and operations; rising resistive current means ageing.
Protocols: Modbus TCP · Modbus RTU · IEC 61850
Used in: Semiconductor & IC manufacturing · New-energy manufacturing
4 brands: DEHN, Hitachi Energy, Siemens Energy, ZGF
Surge protective device (SPD) status
A spent SPD no longer protects; its status contact must be watched.
Protocols: Modbus TCP · Modbus RTU
Used in: New-energy manufacturing · Data centers · Commercial buildings
5 brands: CITEL, DEHN, nVent, Phoenix Contact, ZGF
Switchgear wireless temperature
Wireless sensors on bus bars, contacts and cable lugs find hot joints.
Protocols: Modbus TCP · IEC 61850 · Modbus RTU
Used in: Semiconductor & IC manufacturing · Data centers · General & discrete manufacturing
6 brands: Cementys, Exertherm, Fluke, Huacheng, Schneider Electric, Yingnuo
Tenant submeter
Meters each tenant's power for billing and to spot unusual use. Read-only.
Protocols: Modbus TCP · BACnet/IP · Modbus RTU · DL/T 645 · M-Bus · DNP3 · IEC 61850
Used in: Data centers · Commercial buildings
46 brands: ABB, ABB China, Accuenergy, Acrel, Badger Meter, Camille Bauer, Carlo Gavazzi, Chint, Circutor, CLOU, Continental Control Systems, Delixi, DENT Instruments, Diehl Metering, E-Mon, Eastron, Electro Industries/GaugeTech, Elspec, Finder, Gossen Metrawatt, Haoningda, Hexing, Huizhong, Iskra, Itron, Janitza, Kamstrup, Landis+Gyr, Leviton, Linyang, Lovato Electric, Neptune Technology, Sanchuan, Sanxing, SATEC, Schneider Electric, Sensus, Sfere, Siemens, Socomec, Sunrise, Suntront, Veris, Wasion, XJ Meter, YADA
Tool PDU / EMO
Tool power distribution and emergency off; EMO is pressed at the tool, read-only here.
Protocols: SNMP v3 · Modbus TCP
Used in: Semiconductor & IC manufacturing · Electronics & flat-panel display
3 brands: ACM Research, Raritan, Schneider Electric
Transfer switch
The ATS automatically transfers to the other source when one fails. It switches on its own; the platform only records and notifies.
Protocols: Modbus TCP · Modbus RTU
Used in: Data centers
13 brands: ABB, ASCO, Chint, CNC, Deep Sea Electronics, Liangxin, Lovato Electric, Russelectric, Schneider Wangao, SmartGen, Socomec, TENGEN, Zenith
Transformer
Steps utility voltage down to 480 V. High winding temperature shortens its life or burns it out.
Protocols: Modbus TCP · Modbus RTU · IEC 61850 · DNP3
Used in: Electronics & flat-panel display · Biopharma & life sciences · General & discrete manufacturing
6 brands: Daqo Group, Eaton Cooper Power, Hitachi Energy, Qualitrol, SGB-SMIT, TBEA
Transformer DGA monitor
Analyses gases dissolved in transformer oil; rising hydrogen and acetylene warn of discharge and overheating.
Protocols: IEC 61850 · DNP3 · Modbus TCP
Used in: Semiconductor & IC manufacturing · New-energy manufacturing · Data centers · Copper tube & metal processing
6 brands: Camlin Energy, GE Vernova, Hitachi Energy, Qualitrol, Vaisala, Zhongfen
UPS
On a utility outage, the UPS carries the load on battery for a few minutes until the generators start. Feeds A and B back each other up (2N).
Protocols: SNMP v3 · Modbus TCP · Modbus RTU
Used in: Semiconductor & IC manufacturing · Electronics & flat-panel display · New-energy manufacturing · Biopharma & life sciences · Data centers · Copper tube & metal processing · Glass manufacturing · Healthcare
27 brands: AEG Power Solutions, APC, Borri, CPSY, CyberPower, Delta Electronics, EAST, Eaton, Fuji Electric, Gamatronic, Hitec Power Protection, Huawei, Inspur, Kehua, Kstar, Legrand, Mitsubishi Electric, Piller, Riello, Salicru, Schneider Electric, Socomec, Toshiba, Tripp Lite, Vertiv, Zhongheng, ZTE
UPS battery string monitor
Monitors every jar's voltage, resistance and temperature. A jar with rising resistance fails first in an outage and cuts UPS runtime.
Protocols: Modbus TCP · Modbus RTU · SNMP v3
Used in: Semiconductor & IC manufacturing · Electronics & flat-panel display · New-energy manufacturing · Biopharma & life sciences · Data centers · Glass manufacturing · Healthcare
5 brands: BTECH, Eagle Eye Power Solutions, Narada, Shuangdeng, Vertiv Albér
Voltage stabilizer / AVR
Holds a fluctuating supply near nominal voltage.
Protocols: Modbus TCP · Modbus RTU
Used in: General & discrete manufacturing · Healthcare
7 brands: EAST, Hongbao, IREM, Kehua, Ortea, SEARI, Superior Electric
Weather station
Outdoor temperature, humidity, wind, irradiance and rain for optimised control and PV checks.
Protocols: Modbus TCP · Modbus RTU · DNP3
Used in: New-energy manufacturing · Logistics & warehousing · Commercial buildings
4 brands: Campbell Scientific, OTT HydroMet Lufft, Qingyi, Vaisala
Wind turbine
On-site wind turbine: wind speed, output and yaw.
Protocols: OPC UA · Modbus TCP · DNP3
Used in: New-energy manufacturing · General & discrete manufacturing
4 brands: Bergey Windpower, GE Vernova, Goldwind, Vestas
Winding temperature monitor
Fibre optics measure the winding hot spot directly, run cooling fans and estimate ageing.
Protocols: IEC 61850 · DNP3 · Modbus TCP · Modbus RTU
Used in: Semiconductor & IC manufacturing · Data centers · Copper tube & metal processing
6 brands: Advanced Energy, FISO Technologies, Hitachi Energy, LumaSense, Qualitrol, Yingnuo
A brand that is not listed can still be connected if the device speaks one of the supported protocols: it starts from the generic protocol template and is adjusted to the vendor's point list.