Biopharma & life sciences

Biologics, small-molecule API, sterile fill-finish, vaccines, cell and gene therapy, QC labs, vivaria and medical devices: clean utilities, GMP environmental monitoring and the cold chain.

How FacilityOS helps

Platform modules used

Segments

Systems and equipment

Core: every site of this kind has it. Common: most sites have it. Optional: depends on the site.

Heating & cooling plant

GMP temperature and humidity depend on steady chilled water and steam.

EquipmentLevelPoints worth watchingNotes
ChillerCoreCHW supply temp · CHW return temp · Load · Power draw · Efficiency · FaultMid-size plant chillers on BACnet/IP.
Cooling tower cellCoreTower leaving water · Tower entering water · Fan speed · Basin level · Water conductivity · Fan vibration
PumpCoreRunning · Speed · Differential pressureChilled and condenser water pumps; drives usually on Modbus TCP.
Steam boilerCommonSteam pressure · Firing rate · Drum water level · Low-water cutoff · Fault
Hot-water boilerCommonHot water supply temp · Hot water return temp · Firing rate · Flue gas temp · Fault
Heat-recovery chiller / heat pumpOptionalHot water supply temp · Chilled water supply temp (recovery side) · Power draw · Combined COPHeat recovery displacing boiler gas — one of the main decarbonization levers.
Absorption chillerOptionalCHW supply temp · Crystallization alarm

GMP HVAC & cleanrooms

Grade A/B/C/D cascades, particles and T/RH are recorded by the EMS.

EquipmentLevelPoints worth watchingNotes
Make-up air unitCommonSupply air temp · Supply dew point · Outdoor airflow
Recirculation air unitCoreSupply air temp · Recirculation airflow · Filter pressure dropGMP AHUs, duty/standby or N+1.
GMP cleanroomBiologics (mAb / protein) · Sterile fill-finish · Vaccines · Cell & gene therapy · Small-molecule APICorePressure vs adjacent lower grade · Room temp · Relative humidity · Particles ≥ 0.5 µm · Particles ≥ 5.0 µm · Air changes per hour · Door held openTypical cascade 10–15 Pa (0.04–0.06 inWC).
Grade A zone (RABS / isolator)Sterile fill-finish · Cell & gene therapy · VaccinesCoreParticles ≥ 0.5 µm · Particles ≥ 5.0 µm · Unidirectional airflow velocity · Pressure vs background room · Glove breachAnnex 1 Grade A limit 3,520/m³ ≥ 0.5 µm (about 100/ft³); about 90 fpm (0.45 m/s) is the usual guidance for unidirectional flow.
Cleanroom zoneMedical devicesCorePressure vs adjacent · Room temp · Relative humidity · Target class (ISO 14644-1)ISO 7–8 assembly cleanrooms.
GMP environmental monitoring systemCoreOpen cleanroom excursions · Open cold-chain excursions · Sensors offlineA validated, independent EMS (e.g. Vaisala viewLinc, Rees) is the system of record.
Vivarium roomVivariumCoreRoom temp · Relative humidity · Pressure vs corridor · Air changes per hour · Light level · Photoperiod: lights on
Biosafety cabinetCell & gene therapy · QC laboratories · VaccinesCoreInflow velocity · Downflow velocity · Airflow alarm · Sash out of position
Fume hoodQC laboratories · Small-molecule APICoreFace velocity · Sash opening · Low airflow
HumidifierCommonControlled humidity · Cylinder / nozzle service
Pass-through / airlock interlockCommonBoth doors open · UV lamp hours

Clean utilities: PW, WFI, clean steam

Conductivity and TOC are release limits; cool WFI loses self-sanitization.

EquipmentLevelPoints worth watchingNotes
Reverse osmosis unitCorePermeate conductivity · Permeate flow
Electrodeionization unitCoreProduct resistivity
Purified water loopCoreConductivity (25°C comp.) · TOC · Loop temp · Loop ozone · Ozone-destruct UV onUSP <645> conductivity and USP <643> TOC (500 ppb typical limit).
Multi-effect WFI stillBiologics (mAb / protein) · Sterile fill-finish · Vaccines · Small-molecule APICoreWFI output · Distillate conductivity · Heating steam pressure · Off-spec water diverted
Water for injection loopBiologics (mAb / protein) · Sterile fill-finish · Vaccines · Small-molecule APICoreConductivity (25°C comp.) · TOC · Loop temp · Return flowHot loops typically run near 80°C (176°F).
Clean steam generatorBiologics (mAb / protein) · Sterile fill-finish · Vaccines · Cell & gene therapy · Small-molecule APICoreClean steam pressure · Clean steam temp · Condensate conductivity
Clean-in-place skidBiologics (mAb / protein) · Vaccines · Small-molecule APICommonCIP supply temp · Caustic concentration · Supply flow · CIP cycle failed
pH neutralization systemCommonEffluent pH · FlowIncluding bio-kill.
Domestic water boosterCommonDischarge pressure · Flow
Steam trap monitoringOptionalTraps failed · Estimated steam loss
Condensate return unitOptionalConductivity

Process equipment (monitor only)

The batch system runs the process; the platform confirms utilities keep up.

EquipmentLevelPoints worth watchingNotes
Bioreactor (utility monitoring)Biologics (mAb / protein) · Vaccines · Cell & gene therapyCoreVessel temp · pH · Dissolved oxygen (% sat.) · Agitation
AutoclaveSterile fill-finish · Biologics (mAb / protein) · Vaccines · Cell & gene therapy · QC laboratories · Vivarium · Medical devicesCoreChamber temp · Chamber pressure · Cycle phase (0 idle … 5 dry) · Cycle aborted
CO2 incubatorCell & gene therapy · QC laboratories · VaccinesCoreChamber temp · CO2 · Chamber humidity · Door open
Freeze dryer (lyophilizer)CommonChamber pressure · Batch alarm
Isolator / RABSCommonPressure to room · Glove leak test failed
Vial washerOptionalWFI temp · WFI pressure
Depyrogenation tunnelOptionalHot-zone temp
Aseptic filling lineCommonFill rate · Reject rate
Chromatography skidCommonUV absorbance · Over-pressure
Ultrafiltration / TFF skidCommonTransmembrane pressure
Solution preparation systemCommonTank level · Batch alarm

Cold chain

2–8°C, −20°C, −80°C and LN2 vapor storage; excursions need QA review.

EquipmentLevelPoints worth watchingNotes
Cold room (2–8°C)CoreRoom temp · Door left open · Refrigeration power failure
Freezer (−20°C)CoreCabinet temp · Door open · Power failure
Ultra-low freezer (−80°C)CoreCabinet temp · Power failure · LN2/CO2 backup cooling on−80°C (−112°F), often with LN2/CO2 backup.
LN2 vapor-phase freezerCell & gene therapy · Biologics (mAb / protein) · VaccinesCoreVapor-phase temp (top) · LN2 level · Filling · Lid open
Medical refrigeratorQC laboratories · Cell & gene therapyCommonCabinet temp · Door openLab and stability refrigerators.
Temperature mapping setCommonColdest logger · Warmest logger · Mean kinetic temperature (MKT) · Loggers reportingWarehouse and cold-room temperature mapping.
Stability chamberCommonChamber temp · Excursion

Compressed air & process gases

Product-contact air must be oil-free and dry; CO2, O2 and N2 feed bioreactors and inerting.

EquipmentLevelPoints worth watchingNotes
Air compressorCoreDischarge pressure · Load · Power draw · Fault
Desiccant air dryerCorePressure dew point · Pressure drop · Regeneration temp · FaultDew point usually specified as an ISO 8573-1 class, e.g. −40°F.
Compressed-air headerCommonHeader pressure · Air demand · Receiver pressure
Bulk gas supplyCoreTank level · Supply pressure · Vaporizer outlet temp · Flow · Impurity · Reserve supply in useN2, O2, Ar, H2, CO2; tank telemetry is usually the gas supplier's.
Oxygen deficiency monitorCoreOxygen · Alarm 1 (O2 below 19.5 %) · Alarm 2 (O2 below 18 %)LN2 storage and CO2 areas.
Cryogenic vaporizerCommonOutlet gas temp · Low outlet temp

Exhaust

Lab and process exhaust; solvent oxidizers.

EquipmentLevelPoints worth watchingNotes
Process exhaust systemCoreExhaust main static · Exhaust airflow · Fans running · Low exhaust staticWatch general, heat, solvent and acid exhaust separately; N+1 fans.
Regenerative thermal oxidizerSmall-molecule APICommonCombustion chamber temp · Inlet solvent (LEL) · Bypass damper open
Exhaust fanCommonRunning · Speed

Power & sub-metering

The EMS, cold chain and Grade B HVAC must be on emergency power.

EquipmentLevelPoints worth watchingNotes
Medium-voltage switchgearCoreBus voltage · Incoming current · Real power · Breaker closed · Protective trip · Relay troubleMonitor only — never operate breakers.
Low-voltage switchgearCoreBus voltage · Load current · Real power · Power factor · Current THD · Breaker trip
Power transformerCommonTop-oil temp · Winding temp · Load · Gas / sudden-pressure alarm · Over-temperature alarm
TransformerCommonWinding temp · Load · Over-temperature alarmDry-type transformers.
UPSCoreLoad · Battery runtime · On bypassSNMP v3 (UPS-MIB).
UPS battery string monitorCoreString voltage · Lowest jar voltage · Highest jar voltage · Highest jar internal resistance · Highest jar temp · State of chargePer-jar resistance trending (one of the maintenance practices in IEEE 1188).
GeneratorCoreRunning · Output power · Fuel tank level · Starting battery voltage · Not in AUTO
Branch transfer switchCommonOn emergency source · Normal source available · Emergency source available
Power quality meterCommonVoltage THD · Current THD · Voltage sags today · Sag / interruption eventVoltage sags are a common hidden cause of trips.
Site utility meterCoreSite power · Site power (MW) · Energy today · Power factor
Area energy meterCoreArea power · Energy today · 15-min demand · Power factorSub-metering by workshop or system for energy analysis and cost allocation.
Natural gas meterCommonNatural gas flow · Heat input (1,037 BTU/scf) · Gas today (scf)Natural gas in scfh, converted to BTU/h by heating value.

Life safety Monitor only

Fire, leaks and solvent vapour. Monitor only.

EquipmentLevelPoints worth watchingNotes
Fire alarm zone & linkageCoreFire alarm · Supervisory · Trouble · Linkage: air handlers stopped · Linkage: fire/smoke dampers closed · Linkage: smoke exhaust running · Linkage: elevators recalledLinkage proofs verify the fire system did what it should.
Fire alarm panelCoreFire alarm · Supervisory signal · Trouble signalMonitor only (NFPA 72).
Aspirating smoke detectorCommonSmoke obscuration (%/ft) · Alert · Action · Fire 1 · Airflow fault
Leak detection cableCoreLeak detected · Distance to leak · Leak zone · Cable break or contamination
Sprinkler riserCommonRiser pressure · Waterflow alarm · Valve tamper
Combustible gas detectorSmall-molecule APICoreCombustible gas (LEL) · Gas alarm
Pre-action / dry-pipe valveCommonAir pressure · Valve tripped · Low air

Security & video Monitor only

Camera and door status, and video linkage: cameras are linked to areas, devices and alarm rules; on an alarm the gateway takes an ONVIF snapshot and attaches it to the alarm, with a live-view link to the NVR/VMS. Core never contacts a camera.

EquipmentLevelPoints worth watchingNotes
Video cameraCommonOnline · Recording · Motion detected · Video analytics alarm · Tamper (blocked or moved)Status via the VMS (Milestone, Genetec…); on an alarm the gateway takes an ONVIF snapshot and attaches it to the alarm — Core never contacts a camera.
Access-controlled doorCoreDoor open · Door held open · Door forcedGMP suites and cell-bank access.

Life-safety equipment (fire alarm, gas detection, emergency power transfer) and protection devices are monitored only. FacilityOS never sends them commands.

Standards and compliance

Standards and complianceNotes
EU GMP Annex 1 (2022)Manufacture of sterile medicinal products: Grade A–D cleanrooms, environmental monitoring and contamination control strategy. Grade A ≥ 0.5 µm limit 3,520/m³.
21 CFR Part 11Electronic records and electronic signatures.
21 CFR 210/211Current good manufacturing practice for finished pharmaceuticals.
FDA Aseptic Processing Guidance (2004)Guidance for sterile drug products produced by aseptic processing.
ISO 14644-1 / -2Cleanroom classification and ongoing monitoring.
USP <645> / <643> / <1231>Water conductivity, total organic carbon and water for pharmaceutical purposes.
ISPE Baseline Guide Vol. 4Water and steam systems.
GAMP 5A risk-based approach to compliant GxP computerized systems.
WHO TRS 961 Annex 9Model guidance for storage and transport of time- and temperature-sensitive pharmaceutical products.
NSF/ANSI 49Biosafety cabinetry design, performance and field certification.
ISO 13485Medical devices quality management systems.
NFPA 72National Fire Alarm and Signaling Code.

Standards are listed with what they cover; numeric values are typical figures, not requirements for every site. FacilityOS supports your compliance work; it does not certify a site.

KPIs the platform tracks

KPIs the platform tracksNotes
Grade B ΔP low pointLowest pressure across Grade B rooms.
WFI TOCWFI loop TOC (ppb) against alert and action levels.
Cold-chain excursionsOpen cold-chain excursions in the EMS.
EM excursion rateMonthly excursions ÷ monitoring points.
Utility availabilityShare of time PW, WFI and clean steam were in spec.

Reports

ReportsNotes
Monthly environmental monitoring reportPer-grade pressure, particle and T/RH excursions and trends for QA product quality review.
Pharmaceutical water reportPW and WFI conductivity, TOC, temperature and excursions.
Cold-chain excursion reportStart, peak, duration and disposition of each excursion.
Audit-trail reportSetpoint changes, acknowledgements and signatures (21 CFR Part 11).

How we deliver

We can take a Biopharma & life sciences project from survey and design through procurement, installation, commissioning and training — all of it, or only the stages you need.

  1. Site survey & needs assessment
  2. Solution design
  3. Procurement
  4. Installation
  5. Commissioning & acceptance
  6. Training
  7. Go-live & support

Demo site

Durham Biologics Plant

A monoclonal-antibody and aseptic fill-finish plant: PW, WFI and clean steam, a Grade A/B/C/D pressure cascade, single-use bioreactors and a 2–8°C to −80°C cold chain.

Open the Durham Biologics Plant demo site to see this industry with simulated live data: process graphics, video wall, alarm drills and remote adjustment.

Try the live demo

See it with your own equipment

Open the live demo now, or tell us about your site and we will map your equipment and systems to FacilityOS.