Schneider Electric
FacilityOS recognizes Schneider Electric equipment during a network scan and connects it over SNMP v3, Modbus TCP, BACnet/IP, IEC 61850, DNP3, Modbus RTU, OPC UA.
Region: Europe · Category: Power, Cleanroom, Air side, Cooling plant, Exhaust & abatement, Process
Product families
| Product families | Device types | Protocols | How it connects | |
|---|---|---|---|---|
| Galaxy VX / VM / VS / VL · Symmetra PXGalaxy VX · Galaxy VM · Galaxy VS · Galaxy VL · Symmetra PX · Symmetra | UPS | SNMP v3 · Modbus TCP | Network Management Card (AP9640/AP9641 = NMC3, AP9630/AP9631 = NMC2) | Read-only Point map available |
| PowerLogic PM5000 (PM5100 / PM5300 / PM5500 / PM5600 / PM5700)PM5110 · PM5310 · PM5320 · PM5330 · PM5340 · PM5560 · PM5563 · PM5580 · PM5650 · PM5760 | Area energy meter, Building main meter, Tenant submeter, Main switchgear meter | Modbus TCP · BACnet/IP | PM53xx and up: Ethernet Modbus TCP built in; BACnet/IP on PM55xx/PM56xx with current firmware; PM51xx: RS-485 only | Point map available |
| PowerLogic PM8000 (PM8240 / PM8243 / PM8244)PM8000 · PM8240 · PM8243 · PM8244 | Area energy meter, Building main meter, Main service meter, Main switchgear meter | BACnet/IP · Modbus TCP | Built-in Ethernet: Modbus TCP, BACnet/IP, ION | Point map available |
| PowerLogic ION9000 / ION9000TION9000 · ION9000T · ION9200 | Main switchgear meter, Site utility meter, Hospital main meter, Power quality analyzer (Class A) | BACnet/IP · Modbus TCP · IEC 61850 | Built-in Ethernet: Modbus TCP, IEC 61850, BACnet/IP, DNP3 | Read-only Point map available |
| Easergy P3 / P5 · Sepam series 80P3F30 · P3U30 · P5F30 · Sepam S80 · Sepam T87 | Protection relay | IEC 61850 · Modbus TCP · DNP3 | Built-in Ethernet: IEC 61850, Modbus TCP, DNP3 (Sepam: ACE850 module) | Read-only Point map available |
| EcoStruxure Building (SpaceLogic AS-P / MP / RP), Andover ContinuumAS-P · MP-C · RP-C · bCX1 | Air handler, VAV zone, Fan coil unit, VAV air handler | BACnet/IP | BACnet/IP or MS/TP built in | To be confirmed |
| Uniflair LE / TDAV / InRowTDAV · TDCV · ACRC | CRAH, CRAC (DX) | Modbus TCP · SNMP v3 · BACnet/IP | NMC / pCO card: SNMP, Modbus, BACnet | To be confirmed |
| PowerLogic ION7400 / ION7650 / PM2000ION7400 · ION7650 · PM2220 · PM2230 | Tenant submeter, Area energy meter, Main switchgear meter, Building main meter | Modbus TCP · Modbus RTU · BACnet/IP | RS-485 Modbus RTU; Modbus TCP on Ethernet models | To be confirmed |
| Altivar ATV212 / ATV600 / ATV900ATV212 · ATV630 · ATV650 · ATV930 | Pump, Exhaust fan | Modbus TCP · Modbus RTU · BACnet/IP | Built-in Modbus RTU / TCP; BACnet option | To be confirmed |
| Modicon M580 / M340 / M221 / M251BMEP58 · BMXP34 · TM221 · TM251 | Redundant controller CPU | Modbus TCP · OPC UA | Ethernet Modbus TCP / OPC UA | To be confirmed |
| EVlink Pro AC / Pro DCEVlink Pro AC · EVlink Pro DC | EV chargers | Modbus TCP | Charger Modbus TCP (or OCPP through a local gateway) | To be confirmed |
| SM AirSeT / Premset / Okken / Model 6 MCC / I-LINESM AirSeT · Premset · Okken · Model 6 · I-LINE | Medium-voltage switchgear, Low-voltage switchgear, Motor control center, Overhead busway | Modbus TCP · IEC 61850 | EcoStruxure Panel Server Modbus, read-only | Read-only To be confirmed |
| EcoStruxure Power Monitoring Expert / Power OperationPower Monitoring Expert · Power Operation · PME | Power monitoring | OPC UA · Modbus TCP | OPC UA server | To be confirmed |
| PowerLogic ION8650 revenue metersION8650 · ION8800 | Main service meter, Hospital main meter, Site utility meter | Modbus TCP · DNP3 | RS-485 Modbus RTU; Modbus TCP on Ethernet models | To be confirmed |
| EcoStruxure Hotel Room ControllerRoom Controller RC · SpaceLogic RP-C | Guest room control unit | BACnet/IP | BACnet/IP or MS/TP built in | To be confirmed |
| RM6 / RM AirSeT ring main unitsRM6 · RM AirSeT | Ring main unit | Modbus TCP · IEC 61850 · DNP3 | Easergy T300 RTU, read-only | Read-only To be confirmed |
| Vigilohm IM20 / IM400 / Vigilohm IFLIM20 · IM400 · IFL12 | Insulation monitoring device (IT system), Residual current monitor (RCM) | Modbus TCP | Modbus, read-only | Read-only To be confirmed |
| Square D isolated power panelsIsolated Power Panel · IPP | Isolated power panel (LIM) | Modbus TCP | LIM Modbus, read-only | Read-only To be confirmed |
| EcoStruxure Microgrid Advisor / OperationMicrogrid Advisor · Microgrid Operation | Microgrid controller | Modbus TCP · OPC UA · DNP3 | Modbus / OPC UA, read-only | Read-only To be confirmed |
| AccuSine PCS+ / EVC+ / PFV+AccuSine PCS+ · AccuSine EVC+ · AccuSine PFV+ | Active harmonic filter (APF), Static var generator (SVG / STATCOM), Hybrid harmonic filter | Modbus TCP | Ethernet / RS-485 Modbus (target PF and mode writable with approval) | To be confirmed |
| Square D K-factor / NL / harmonic mitigating transformersSquare D NL · K-13 · Harmonic Mitigating | Isolation / K-rated transformer, Phase-shifting (harmonic-mitigating) transformer | Modbus TCP | Temperature controller Modbus | To be confirmed |
| Easergy TH110 / CL110 (EcoStruxure Substation Monitoring)TH110 · CL110 | Switchgear wireless temperature | Modbus TCP | Monitor Modbus / IEC 61850 / DNP3, read-only | Read-only To be confirmed |
| VAMP 120 / 321 arc flash protectionVAMP 120 · VAMP 321 | Arc-flash protection relay | Modbus TCP · IEC 61850 | Monitor Modbus / IEC 61850 / DNP3, read-only | Read-only To be confirmed |
| InRow RD / RC, EcoAisle, NetBotzInRow RD · EcoAisle · NetBotz 750 | In-row cooler, Aisle containment, Rack environment sensor | SNMP v3 · Modbus TCP · BACnet/IP | NMC: SNMP / Modbus / BACnet | To be confirmed |
| Tool power distribution / EMO panelsTool PDU · EMO panel | Tool PDU / EMO | Modbus TCP | Modbus, read-only | Read-only To be confirmed |
To be confirmed Point map to be confirmed against the vendor's register list before use.
Read-only This family is always read-only in FacilityOS.
A brand that is not listed can still be connected if the device speaks one of the supported protocols: it starts from the generic protocol template and is adjusted to the vendor's point list.