Logistics & warehousing

Distribution centers, cold storage and e-commerce fulfilment: refrigeration, docks, sortation, forklift charging and lighting.

How FacilityOS helps

Platform modules used

Segments

Systems and equipment

Core: every site of this kind has it. Common: most sites have it. Optional: depends on the site.

Refrigeration

Lose temperature and the product is lost.

EquipmentLevelPoints worth watchingNotes
Ammonia compressorCold chain / cold storageCoreSuction pressure · Discharge pressure · Slide valve (load) · Power draw
Evaporative condenserCold chain / cold storageCoreCondensing pressure · Fan speed · Receiver level
Refrigeration rackCold chain / cold storageCommonSuction pressure · Discharge pressure · Compressors running · Refrigerant leak levelHFC or CO2 racks.
Freezer roomCold chain / cold storageCoreRoom temp · Evaporator coil temp · Defrosting · Door left open
Cooler roomCold chain / cold storageCoreRoom temp · Room humidity · Door left open
Temperature mapping setCold chain / cold storage · Distribution centerOptionalColdest logger · Warmest logger · Mean kinetic temperature (MKT)
Split DX / condensing unitCommonSuction pressure · High-pressure trip

Materials handling

The sorter is the throughput bottleneck.

EquipmentLevelPoints worth watchingNotes
ConveyorCoreBelt speed · Cartons per hour · Jam
Sortation systemDistribution center · E-commerce fulfilmentCoreSort rate (cartons/h) · Sorted today · Recirculation · Jam
Dock door bankCoreDock doors open · Trailers at doors · Door open, no trailer · Leveler fault
AGV / AMR fleetCommonVehicles working · E-stop · Tasks queued
Automated storage and retrieval (AS/RS)CommonAvailability · Crane fault
PalletizerCommonRate · Fault
Packaging / labelling lineCommonOEE
Weighbridge / scaleOptionalCurrent weight · Load cell fault
Trash compactorCommonFullness · Full

Ventilation & heating

Comfort and freeze protection in big spaces.

EquipmentLevelPoints worth watchingNotes
HVLS fanCommonSpeed · Power draw
Gas unit heaterCoreZone temp · Gas valve
Rooftop unitCommonZone temp · Power draw
VRF outdoor unitCommonPower · Error code
Electric heaterOptionalHeating power · High limit tripped
Weather stationCommonOutdoor temp · Wind speed

Lighting

Dimming with activity.

EquipmentLevelPoints worth watchingNotes
High-bay LED zoneCoreLight level · Occupied · Lighting power

Power & energy

Forklift charging and refrigeration are the big loads; rooftop PV offsets them.

EquipmentLevelPoints worth watchingNotes
Main service meterCoreSite power · Energy today · Solar share
Forklift charging roomCoreBatteries charging · Charging power · Hydrogen alarm (charging room)
Rooftop solar inverterCommonSolar output · Energy today
GeneratorOptionalRunning · Output power · Fuel tank level · Starting battery voltage · Not in AUTO
EV chargersOptionalCharging power
Power quality meterCommonVoltage THD · Current THD · Voltage sags today · Sag / interruption eventVoltage sags are a common hidden cause of trips.
Automatic capacitor bankCommonPower factor · Capacitor current, measured / rated · Resonance alarm · Switching operations today
Power factor controllerCommonPower factor · Under-compensated · Over-compensated
Rainwater harvestingOptionalCistern level · Turbidity

Life safety Monitor only

High-piled sprinklers and ammonia leaks. Monitor only.

EquipmentLevelPoints worth watchingNotes
Fire alarm panelCoreFire alarm · Supervisory signal · Trouble signalMonitor only (NFPA 72).
Fire pumpCommonRunning · System pressure · Power phase failure
Sprinkler riserCoreRiser pressure · Waterflow alarm · Valve tamper
Smoke exhaust fanCommonRunning · Damper not provenSmoke exhaust or stair pressurization fans; monitor only.
Ammonia detectorCold chain / cold storageCoreAmmonia level · Ammonia alarm
Central emergency lighting supply (EPS)CoreBattery fault · Days since 90-min test
Pre-action / dry-pipe valveCommonAir pressure · Valve tripped · Low air

Security & video Monitor only

Camera and door status, and video linkage: cameras are linked to areas, devices and alarm rules; on an alarm the gateway takes an ONVIF snapshot and attaches it to the alarm, with a live-view link to the NVR/VMS. Core never contacts a camera.

EquipmentLevelPoints worth watchingNotes
Video cameraCommonOnline · Recording · Motion detected · Video analytics alarm · Tamper (blocked or moved)Status via the VMS (Milestone, Genetec…); on an alarm the gateway takes an ONVIF snapshot and attaches it to the alarm — Core never contacts a camera.
Access-controlled doorCommonDoor open · Door forced
Intrusion alarm panelCommonIntrusion alarm · Tamper
Guard tourOptionalMissed checkpoints · Man-down alarm

Life-safety equipment (fire alarm, gas detection, emergency power transfer) and protection devices are monitored only. FacilityOS never sends them commands.

Standards and compliance

Standards and complianceNotes
IIAR 2Safe design of ammonia refrigeration systems.
IIAR 9Minimum safety criteria for existing ammonia refrigeration systems.
ASHRAE 15Safety standard for refrigeration systems.
EPA Section 608Refrigerant management (leak repair and records).
FDA FSMA Sanitary Transportation RuleSanitary transportation of human and animal food, including temperature control.
NFPA 13Installation of sprinkler systems, including high-piled storage.
OSHA 29 CFR 1910.178Powered industrial trucks, including battery charging areas.

Standards are listed with what they cover; numeric values are typical figures, not requirements for every site. FacilityOS supports your compliance work; it does not certify a site.

KPIs the platform tracks

KPIs the platform tracksNotes
Temperature complianceShare of time each room stayed in range.
Sort rateCartons per hour against design.
Energy per cartonkWh ÷ cartons shipped.
Solar shareSolar ÷ site energy.

Reports

ReportsNotes
Cold-chain temperature reportRoom temperatures, defrosts and door openings (FSMA).
Refrigerant leak logLeak rates and repairs (EPA 608).
Energy reportRefrigeration, charging and lighting split.

How we deliver

We can take a Logistics & warehousing project from survey and design through procurement, installation, commissioning and training — all of it, or only the stages you need.

  1. Site survey & needs assessment
  2. Solution design
  3. Procurement
  4. Installation
  5. Commissioning & acceptance
  6. Training
  7. Go-live & support

Demo site

Memphis Distribution Center

An 800,000 sq ft distribution center running 24/7: ammonia cold storage, a high-speed sorter and rooftop solar.

Open the Memphis Distribution Center demo site to see this industry with simulated live data: process graphics, video wall, alarm drills and remote adjustment.

Try the live demo

See it with your own equipment

Open the live demo now, or tell us about your site and we will map your equipment and systems to FacilityOS.