FacilityOS recognizes Siemens equipment during a network scan and connects it over IEC 61850, DNP3, BACnet/IP, S7, Modbus TCP, OPC UA, Modbus RTU, KNX.

Region: Europe · Category: Power, Life safety, Process, Cleanroom, Air side, Cooling plant, Exhaust & abatement, Lighting, Water systems, Medical systems, Heating, Gases & vacuum

Product families

Product familiesDevice typesProtocolsHow it connects
SIPROTEC 5 (7SJ82 / 7SJ85 / 7SA87 / 7UT85) · SIPROTEC 4 (7SJ62 / 7SJ64)7SJ82 · 7SJ85 · 7SA87 · 7UT85 · 7SJ62 · 7SJ64 · 7SJ80Protection relayIEC 61850 · DNP3SIPROTEC 5: built-in Ethernet module (IEC 61850); SIPROTEC 4: EN100 moduleRead-only Point map available
Desigo Fire Safety Modular · Cerberus PRO (FC2080 / FC2025)FC2080 · FC2025 · FC2060 · Desigo Fire Safety ModularFire alarm panel, Fire alarm zone & linkageBACnet/IPRead-only through a BACnet gateway or Desigo CCRead-only Point map available
SIMATIC S7-1500 / S7-1500R/H / S7-1200S7-1500 · S7-1200 · CPU 1515R · CPU 1517H · CPU 1516-3Redundant controller CPUS7 · Modbus TCP · OPC UABuilt-in PROFINET port: S7 (PUT/GET and non-optimised DBs), Modbus TCP, OPC UA server Point map available
SENTRON PAC3200 / PAC4200 / PAC2200PAC3200 · PAC4200 · PAC2200 · PAC3220Tenant submeter, Area energy meter, Main switchgear meterModbus TCP · Modbus RTUBuilt-in Ethernet Modbus TCP; RS-485 module To be confirmed
Desigo PXC / PXC4 / PXC7 / DXRPXC4.E16 · PXC7.E400 · PXC100 · DXR2.E10Air handler, VAV zone, Fan coil unit, VAV air handlerBACnet/IPBACnet/IP or MS/TP built in To be confirmed
SINAMICS G120 / G120X / G150G120 · G120X · G150 · G120CPump, Exhaust fanModbus TCP · BACnet/IP · S7Built-in Modbus RTU / BACnet MS/TP; PROFINET through the PLC To be confirmed
GAMMA instabus N 146 / 5WG1N146/02 · 5WG1 146-1AB03High-bay LED zone, Lighting control panelKNXKNXnet/IP (through an IP interface / router) To be confirmed
SITRANS P / F / LRSITRANS P320 · SITRANS FM MAG 5000 · SITRANS LR100Final effluent monitor, Reverse osmosis unitModbus TCP · Modbus RTU4–20 mA / HART through a PLC, or a Modbus / PROFIBUS gateway To be confirmed
QFM / QPM duct and room sensorsQFM3160 · QPM2160 · QFA3160IAQ sensorModbus TCP · Modbus RTU · BACnet/IPRS-485 Modbus RTU; Modbus TCP on Ethernet models To be confirmed
NXAIR / SIVACON S8 / tiastar MCC / SENTRON buswayNXAIR · SIVACON S8 · tiastar · SENTRON buswayMedium-voltage switchgear, Low-voltage switchgear, Motor control center, Overhead buswayModbus TCP · IEC 61850SENTRON PAC / 3WA Modbus, read-onlyRead-only To be confirmed
SENTRON powermanager / WinCC OASENTRON powermanager · powermanagerPower monitoringOPC UA · Modbus TCPOPC UA server To be confirmed
Desigo room pressurisation / ROMSDXR2.E18 · ROMSCleanroom zone, GMP cleanroom, Isolation room (AIIR), Operating room, Grade A zone (RABS / isolator), Vivarium room, Dry roomBACnet/IPRoom pressure / environment monitor BACnet / Modbus To be confirmed
SINUMERIK 828D / 840D sl / ONE828D · 840D sl · SINUMERIK ONECNC machining centerOPC UASINUMERIK OPC UA To be confirmed
WinCC OA / Opcenter ExecutionWinCC OA · Opcenter ExecutionCleanroom FMCS summary, Cell plant energy KPIsOPC UAOPC UA server To be confirmed
ULTRAMAT 23 / OXYMAT 6 / SIPROCESSULTRAMAT 23 · OXYMAT 6 · SIPROCESS GA700Continuous emissions monitor (CEMS)Modbus TCP · OPC UAAnalyzer Modbus / OPC UA, read-onlyRead-only To be confirmed
Acvatix VPF / EvalveEvalve · VPF43 · SAV81Motorized valveBACnet/IP · Modbus TCPController BACnet / Modbus (built in or with a card) To be confirmed
Synco RMH / Climatix heating substationsRMH760B · ClimatixDistrict heating substation, Plate heat exchangerBACnet/IP · Modbus TCPController BACnet / Modbus (built in or with a card) To be confirmed
LMV5 / LMV3 burner managementLMV52 · LMV37Hot-water boiler burner controlModbus TCPOCI412 Modbus, read-onlyRead-only To be confirmed
SIVACON S8 PQ / SINAMICS AFE (Active Line Module)SIVACON S8 PQ · Active Line Module · SINAMICS S120 ALMActive harmonic filter (APF), Automatic capacitor bank, Active front end (AFE) driveModbus TCP · OPC UAEthernet / RS-485 Modbus (target PF and mode writable with approval) To be confirmed
JFR voltage regulator (MJ-XL control)JFR · MJ-XLStep voltage regulatorDNP3 · Modbus TCPMonitor Modbus / IEC 61850 / DNP3, read-onlyRead-only To be confirmed
SITRANS LR / Probe LU levelSITRANS LR110 · SITRANS Probe LU240Water tank / reservoir level, Tank farm level, Rainwater harvestingModbus TCP · Modbus RTURS-485 Modbus RTU; Modbus TCP on Ethernet models To be confirmed
Sinorix 1230 / Sinorix CDTSinorix 1230 · Sinorix CDTClean-agent suppression panelBACnet/IP · Modbus TCPRead-only through the vendor's BACnet / Modbus interfaceRead-only To be confirmed

To be confirmed Point map to be confirmed against the vendor's register list before use.

Read-only This family is always read-only in FacilityOS.