Water systems
Ultra-pure water, purified water and WFI, process cooling water, wastewater treatment and supply pumps and valves. Water quality and flow set yield and discharge compliance. 26 device types.
Clean steam generator
Makes clean steam from purified water for autoclaves and steam-in-place. Low pressure fails sterilization cycles.
Protocols: Modbus TCP · OPC UA
Used in: Biopharma & life sciences
Clean-in-place skid
Cleans tanks and lines by temperature, concentration, flow and time. Miss any one and the clean does not count.
Protocols: OPC UA · Modbus TCP
Used in: Biopharma & life sciences · General & discrete manufacturing
5 brands: Alfa Laval, Cytiva, GEA, Sartorius, Tofflon
CMP slurry wastewater
Chemical-mechanical polishing waste is full of fine particles; ultrafiltration recovers or discharges it. Effluent turbidity shows how well it works.
Protocols: Modbus TCP · OPC UA
Used in: Semiconductor & IC manufacturing
4 brands: Everbright Water, Kurita, Origin Water, Veolia
Condensate return unit
Returns condensate to save water and fuel; rising conductivity means a leaking exchanger.
Protocols: Modbus TCP · BACnet/IP · MQTT · Modbus RTU
Used in: Biopharma & life sciences · General & discrete manufacturing
4 brands: Armstrong International, Naipu, Spirax Sarco, Watson McDaniel
Domestic hot water
Storage above 140°F prevents Legionella; mixing to about 120°F at the outlet prevents scalding.
Protocols: BACnet/IP · Modbus TCP · KNX
Used in: Commercial buildings · Healthcare
7 brands: A. O. Smith, AERCO, Armstrong International, Lochinvar, PVI Industries, Stiebel Eltron, Viessmann
Domestic hot water recirculation
A warm return keeps Legionella down (ASHRAE 188) and gives hot water at the tap at once.
Protocols: BACnet/IP · Modbus TCP · Modbus RTU
Used in: Commercial buildings · Healthcare
5 brands: Armstrong International, Grundfos, KEMPER, Lochinvar, Vanward
Domestic water booster
Boosts city water pressure enough for the upper floors. If it stops, the high zone has no water.
Protocols: Modbus TCP · Modbus RTU · BACnet/IP
Used in: Semiconductor & IC manufacturing · Electronics & flat-panel display · New-energy manufacturing · Biopharma & life sciences · General & discrete manufacturing · Copper tube & metal processing · Commercial buildings · Healthcare
8 brands: ABB, CNP, Ebara, Grundfos, Kaiquan, KSB, Liancheng, Wilo
Electrodeionization unit
Uses an electric field to keep removing ions from RO water, raising resistivity above 16 MΩ·cm.
Protocols: Modbus TCP · OPC UA
Used in: Semiconductor & IC manufacturing · Electronics & flat-panel display · New-energy manufacturing · Biopharma & life sciences
Final effluent monitor
Flow, pH, COD, fluoride and temperature at the site outfall — the basis of the discharge permit and utility reports. Read-only.
Protocols: Modbus TCP · BACnet/IP · EtherNet/IP · OPC UA · Modbus RTU · DNP3
Used in: Semiconductor & IC manufacturing · Electronics & flat-panel display · New-energy manufacturing · General & discrete manufacturing
12 brands: ABB, Chuanyi, Endress+Hauser, Hach, Krohne, Origin Water, Rosemount, SAI, Siemens, VEGA, Xylem, Yokogawa
Fluoride wastewater treatment
Precipitates fluoride from etch wastewater as calcium fluoride; effluent fluoride must stay under the permit limit.
Protocols: Modbus TCP · OPC UA
Used in: Semiconductor & IC manufacturing
5 brands: Everbright Water, Evoqua, Kurita, Origin Water, Veolia
Irrigation controller
Adjusts watering to the weather to save landscape water.
Protocols: Modbus TCP · MQTT · Modbus RTU
Used in: Commercial buildings
4 brands: Dayu, Gardena, Hunter Industries, Rain Bird
Legionella risk monitoring
Scores Legionella risk from temperature, residual disinfectant and stagnation (ASHRAE 188 water plan).
Protocols: Modbus TCP · BACnet/IP · MQTT · Modbus RTU
Used in: Commercial buildings · Healthcare
5 brands: Grundfos, Hach, KEMPER, Origin Smart, Sloan
Lift station
Lifts drainage from low points to treatment or the sewer. Ignore a high-level alarm and it overflows.
Protocols: Modbus TCP · DNP3 · BACnet/IP · OPC UA · Modbus RTU
Used in: Semiconductor & IC manufacturing
7 brands: Everbright Water, Grundfos, Kaiquan, Origin Water, Wilo, Xylem, Zoeller
Multi-effect WFI still
Distils purified water into WFI with plant steam. Off-spec distillate is diverted automatically.
Protocols: Modbus TCP · OPC UA
Used in: Biopharma & life sciences
pH neutralization system
Neutralizes acid and caustic wastewater to the discharge permit range (typically pH 6–9) before the sewer. Violations bring fines or a shutdown.
Protocols: Modbus TCP · OPC UA · BACnet/IP
Used in: Semiconductor & IC manufacturing · Electronics & flat-panel display · New-energy manufacturing · Biopharma & life sciences · General & discrete manufacturing
5 brands: Everbright Water, Evoqua, Hach, Origin Water, ProMinent
Purified water loop
An ambient, ozonated purified-water loop. Conductivity (USP <645>) and TOC (USP <643>, 500 ppb) are release limits.
Protocols: Modbus TCP · OPC UA
Used in: Biopharma & life sciences
5 brands: BWT, MECO, Mettler-Toledo Thornton, Sievers, Stilmas
Resistivity analyzer
Ultrapure water must stay near 18.2 MΩ·cm.
Protocols: Modbus TCP · OPC UA · Modbus RTU
Used in: Semiconductor & IC manufacturing · Electronics & flat-panel display
4 brands: Hach, Horiba Advanced Techno, Leici, Mettler-Toledo Thornton
Reverse osmosis unit
The first desalting stage of ultra-pure or purified water. Rising permeate conductivity means fouled or damaged membranes.
Protocols: Modbus TCP · OPC UA · BACnet/IP · EtherNet/IP · Modbus RTU
Used in: Semiconductor & IC manufacturing · Electronics & flat-panel display · New-energy manufacturing · Biopharma & life sciences
16 brands: ABB, Chuanyi, Endress+Hauser, Evoqua, Hach, Krohne, Kurita, MECO, Organo, Pall, Rosemount, SAI, Siemens, VEGA, Veolia, Yokogawa
Sewage ejector / grease interceptor
Basement sewage lift and kitchen grease interceptors; high level means an overflow is coming.
Protocols: Modbus TCP · Modbus RTU · BACnet/IP
Used in: Commercial buildings · Healthcare
5 brands: Kaiquan, Liberty Pumps, VEGA, Wilo, Zoeller
Steam trap monitoring
Leaking traps waste a lot of fuel; blocked ones cause water hammer.
Protocols: Modbus TCP · BACnet/IP · MQTT · OPC UA · Modbus RTU
Used in: Biopharma & life sciences · General & discrete manufacturing · Healthcare
5 brands: Armstrong International, Emerson, Naipu, Spirax Sarco, TLV
UPW polishing loop
Ultra-pure water at the tools: 18.2 MΩ·cm resistivity, TOC below 1 ppb, minimal dissolved oxygen and particles. Any of them drifting can hit yield directly.
Protocols: Modbus TCP · OPC UA
Used in: Semiconductor & IC manufacturing · Electronics & flat-panel display
7 brands: Kurita, Mettler-Toledo Thornton, Nomura Micro Science, Organo, Pall, Veolia, Xylem
UV TOC reducer
185 nm UV breaks down organics in the water. As lamps age, TOC creeps up.
Protocols: Modbus TCP · OPC UA
Used in: Semiconductor & IC manufacturing
4 brands: Evoqua, Mettler-Toledo Thornton, Sievers, Xylem
Water for injection loop
WFI circulating hot at 80°C; below about 167°F (75°C) it loses self-sanitization. Water out of conductivity or TOC limits cannot be used.
Protocols: Modbus TCP · OPC UA
Used in: Biopharma & life sciences
5 brands: BWT, MECO, Mettler-Toledo Thornton, Sievers, Stilmas
Water reclaim system
Treats cleaner process drains for reuse in towers or UPW make-up, cutting water use. Off-spec water is diverted to drain automatically.
Protocols: Modbus TCP · OPC UA
Used in: Semiconductor & IC manufacturing · Electronics & flat-panel display
4 brands: Everbright Water, Nomura Micro Science, Origin Water, Veolia
Water softener
Removes hardness to protect boilers, humidifiers and towers; regeneration and salt must keep up.
Protocols: Modbus TCP · Modbus RTU
Used in: General & discrete manufacturing · Commercial buildings · Healthcare
Water tank / reservoir level
Domestic, fire or cooling make-up storage; a fire reserve must never drop below design.
Protocols: Modbus TCP · BACnet/IP · Modbus RTU
Used in: Semiconductor & IC manufacturing · General & discrete manufacturing · Commercial buildings · Healthcare
A brand that is not listed can still be connected if the device speaks one of the supported protocols: it starts from the generic protocol template and is adjusted to the vendor's point list.