Eaton

FacilityOS recognizes Eaton equipment during a network scan and connects it over SNMP v3, Modbus TCP, BACnet/IP, OPC UA, DNP3.

Region: United States · Category: Power, Life safety, Air side

Product families

Product familiesDevice typesProtocolsHow it connects
93PM / 9395 / 93E / 9PX93PM · 9395 · 9395P · 9395XR · 9395XC · 93E · 9PX · 9SXUPSSNMP v3 · Modbus TCPGigabit Network Card (Network-M2 / Network-M3): SNMPv3, Modbus TCPRead-only Point map available
Power Xpert Meter 2000 / 4000 / 6000 / 8000PXM2000 · PXM2250 · PXM2260 · PXM2270 · PXM4000 · PXM6000 · PXM8000Main switchgear meter, Building main meterModbus TCP · BACnet/IP · SNMP v3Built-in Ethernet: Modbus TCP, BACnet/IP, SNMP Point map available
VacClad-W / Magnum / Freedom Flashgard MCC / Pow-R-WayVacClad-W · Magnum DS · Freedom Flashgard · Pow-R-Way IIIMedium-voltage switchgear, Low-voltage switchgear, Motor control center, Overhead buswayModbus TCP · BACnet/IPPXG / Power Xpert gateway Modbus / BACnet, read-onlyRead-only To be confirmed
Brightlayer Electrical Power Manager / Power Xpert InsightBrightlayer EPM · Power Xpert InsightPower monitoringOPC UA · Modbus TCP · BACnet/IPOPC UA / Modbus / BACnet To be confirmed
FD100 / FT1000 fire pump controllersFD100 · FT1000Fire pumpModbus TCPModbus, read-onlyRead-only To be confirmed
ePDU G3 / G4 / PDU power distributionePDU G4 · ePDU G3 · EMAH28PDU, Rack PDUSNMP v3 · Modbus TCPEthernet SNMP / Modbus TCP To be confirmed
Xiria / SVS ring main unitsXiria · SVSRing main unitModbus TCP · DNP3RTU, read-onlyRead-only To be confirmed
Harmonic Correction Unit / Power Xpert C-HRGHCU · Harmonic Correction UnitActive harmonic filter (APF), Power conditionerModbus TCPEthernet / RS-485 Modbus (target PF and mode writable with approval) To be confirmed
AutoVAR 300 / 600 / UnipumpAutoVAR 300 · AutoVAR 600 · UNIPAKAutomatic capacitor bank, Fixed capacitor bankModbus TCPEthernet / RS-485 Modbus (target PF and mode writable with approval) To be confirmed
VR-32 regulator / CL-7 controlVR-32 · CL-7Step voltage regulator, On-load tap changer control (OLTC)DNP3 · Modbus TCPMonitor Modbus / IEC 61850 / DNP3, read-onlyRead-only To be confirmed
Arcflash Reduction Maintenance System / Arc QuenchingARMS · Arc QuenchingArc-flash protection relayModbus TCPMonitor Modbus / IEC 61850 / DNP3, read-onlyRead-only To be confirmed

To be confirmed Point map to be confirmed against the vendor's register list before use.

Read-only This family is always read-only in FacilityOS.

A brand that is not listed can still be connected if the device speaks one of the supported protocols: it starts from the generic protocol template and is adjusted to the vendor's point list.