Eaton
FacilityOS recognizes Eaton equipment during a network scan and connects it over SNMP v3, Modbus TCP, BACnet/IP, OPC UA, DNP3.
Region: United States · Category: Power, Life safety, Air side
Product families
| Product families | Device types | Protocols | How it connects | |
|---|---|---|---|---|
| 93PM / 9395 / 93E / 9PX93PM · 9395 · 9395P · 9395XR · 9395XC · 93E · 9PX · 9SX | UPS | SNMP v3 · Modbus TCP | Gigabit Network Card (Network-M2 / Network-M3): SNMPv3, Modbus TCP | Read-only Point map available |
| Power Xpert Meter 2000 / 4000 / 6000 / 8000PXM2000 · PXM2250 · PXM2260 · PXM2270 · PXM4000 · PXM6000 · PXM8000 | Main switchgear meter, Building main meter | Modbus TCP · BACnet/IP · SNMP v3 | Built-in Ethernet: Modbus TCP, BACnet/IP, SNMP | Point map available |
| VacClad-W / Magnum / Freedom Flashgard MCC / Pow-R-WayVacClad-W · Magnum DS · Freedom Flashgard · Pow-R-Way III | Medium-voltage switchgear, Low-voltage switchgear, Motor control center, Overhead busway | Modbus TCP · BACnet/IP | PXG / Power Xpert gateway Modbus / BACnet, read-only | Read-only To be confirmed |
| Brightlayer Electrical Power Manager / Power Xpert InsightBrightlayer EPM · Power Xpert Insight | Power monitoring | OPC UA · Modbus TCP · BACnet/IP | OPC UA / Modbus / BACnet | To be confirmed |
| FD100 / FT1000 fire pump controllersFD100 · FT1000 | Fire pump | Modbus TCP | Modbus, read-only | Read-only To be confirmed |
| ePDU G3 / G4 / PDU power distributionePDU G4 · ePDU G3 · EMAH28 | PDU, Rack PDU | SNMP v3 · Modbus TCP | Ethernet SNMP / Modbus TCP | To be confirmed |
| Xiria / SVS ring main unitsXiria · SVS | Ring main unit | Modbus TCP · DNP3 | RTU, read-only | Read-only To be confirmed |
| Harmonic Correction Unit / Power Xpert C-HRGHCU · Harmonic Correction Unit | Active harmonic filter (APF), Power conditioner | Modbus TCP | Ethernet / RS-485 Modbus (target PF and mode writable with approval) | To be confirmed |
| AutoVAR 300 / 600 / UnipumpAutoVAR 300 · AutoVAR 600 · UNIPAK | Automatic capacitor bank, Fixed capacitor bank | Modbus TCP | Ethernet / RS-485 Modbus (target PF and mode writable with approval) | To be confirmed |
| VR-32 regulator / CL-7 controlVR-32 · CL-7 | Step voltage regulator, On-load tap changer control (OLTC) | DNP3 · Modbus TCP | Monitor Modbus / IEC 61850 / DNP3, read-only | Read-only To be confirmed |
| Arcflash Reduction Maintenance System / Arc QuenchingARMS · Arc Quenching | Arc-flash protection relay | Modbus TCP | Monitor Modbus / IEC 61850 / DNP3, read-only | Read-only To be confirmed |
To be confirmed Point map to be confirmed against the vendor's register list before use.
Read-only This family is always read-only in FacilityOS.
A brand that is not listed can still be connected if the device speaks one of the supported protocols: it starts from the generic protocol template and is adjusted to the vendor's point list.