ABB
FacilityOS recognizes ABB equipment during a network scan and connects it over IEC 61850, Modbus TCP, DNP3, Modbus RTU, BACnet/IP, M-Bus, OPC UA, KNX, EtherNet/IP.
Region: Europe · Category: Power, Cooling plant, Exhaust & abatement, Water systems, Process, Lighting
Product families
| Product families | Device types | Protocols | How it connects | |
|---|---|---|---|---|
| Relion 615 / 620 (REF615 / RET615 / REM615 / REF620)REF615 · RET615 · REM615 · REU615 · RED615 · REF620 · RET620 · REM620 | Protection relay | IEC 61850 · Modbus TCP · DNP3 | Built-in Ethernet: IEC 61850, Modbus TCP, DNP3 | Read-only Point map available |
| ACH580 / ACS580 / ACS880ACH580 · ACS580 · ACS880 · ACH550 | Pump, Exhaust fan, Domestic water booster | Modbus TCP · Modbus RTU · BACnet/IP | Embedded fieldbus: Modbus RTU / BACnet MS/TP; Modbus TCP with the FENA-21 adapter | Point map available |
| M4M / B-series metersM4M 30 · B23 · B24 | Tenant submeter, Area energy meter | Modbus TCP · Modbus RTU · M-Bus | RS-485 Modbus RTU / M-Bus; Modbus TCP on Ethernet models | To be confirmed |
| TruONE ATSOXA · TruONE | Transfer switch, Branch transfer switch | Modbus TCP | Ekip Com module Modbus, read-only | Read-only To be confirmed |
| AC500 / AC500-eCo / 800xA (AC 800M)PM5650 · PM5630 · AC 800M · 800xA | Redundant controller CPU | Modbus TCP · OPC UA | Ethernet Modbus TCP / OPC UA | To be confirmed |
| ABB i-bus KNX actuators / IP routersIPR/S 3.5.1 · SA/S 8.16.6.2 · DG/S 2.64.1.1 | High-bay LED zone, Lighting control panel | KNX | KNXnet/IP (through an IP interface / router) | To be confirmed |
| ProcessMaster / AquaMaster / AWT420ProcessMaster · AquaMaster4 · AWT420 | Final effluent monitor, Reverse osmosis unit | Modbus TCP · Modbus RTU | 4–20 mA / HART through a PLC, or a Modbus / PROFIBUS gateway | To be confirmed |
| SafeGear / UniGear / MNS / ReliaGearSafeGear · UniGear ZS1 · MNS · ReliaGear | Medium-voltage switchgear, Low-voltage switchgear, Motor control center | IEC 61850 · Modbus TCP | Relays / Ekip IEC 61850 / Modbus, read-only | Read-only To be confirmed |
| AO2000 / ACF5000AO2000 · ACF5000 | Continuous emissions monitor (CEMS) | Modbus TCP · OPC UA | Analyzer Modbus, read-only | Read-only To be confirmed |
| SafeRing / SafePlusSafeRing · SafePlus | Ring main unit | Modbus TCP · IEC 61850 | RTU / relays, read-only | Read-only To be confirmed |
| PQF / PQFS / PQactiF / PQstorIPQFS · PQFM · PQactiF · PQstorI | Active harmonic filter (APF), Static var generator (SVG / STATCOM), Phase unbalance compensator | Modbus TCP | Ethernet / RS-485 Modbus (target PF and mode writable with approval) | To be confirmed |
| PCS100 AVC-40 / RPC / UPS-IPCS100 AVC-40 · PCS100 RPC · PCS100 UPS-I | Dynamic voltage restorer (DVR), Power conditioner, Phase unbalance compensator | Modbus TCP | Ethernet / RS-485 Modbus (target PF and mode writable with approval) | To be confirmed |
| ACS880 ultra-low harmonic / 12-pulse / AFE, du/dt and sine filtersACS880-37 · ACS880-07 12-pulse · NOCH du/dt · B84143 sine | Line / DC-link reactor, Sine-wave filter, dv/dt filter, 12 / 18-pulse front end, Active front end (AFE) drive | Modbus TCP · EtherNet/IP | Drive Modbus / EtherNet/IP | To be confirmed |
| REA 101 / TVOC-2 arc guardREA 101 · TVOC-2 | Arc-flash protection relay | IEC 61850 · Modbus TCP | Monitor Modbus / IEC 61850 / DNP3, read-only | Read-only To be confirmed |
To be confirmed Point map to be confirmed against the vendor's register list before use.
Read-only This family is always read-only in FacilityOS.
A brand that is not listed can still be connected if the device speaks one of the supported protocols: it starts from the generic protocol template and is adjusted to the vendor's point list.