Power & compound semiconductor (SiC / GaN) — Semiconductor & IC manufacturing

Epitaxy and high-temperature processes with heavy H2 and NH3 use; arsine and phosphine for III-V materials.

Power & compound semiconductor (SiC / GaN) is a segment of Semiconductor & IC manufacturing. Below are the systems and equipment FacilityOS covers for it, filtered from the Semiconductor & IC manufacturing solution.

How FacilityOS helps

Systems and equipment

Core: every site of this kind has it. Common: most sites have it. Optional: depends on the site.

Chiller plant & PCW

The plant cools MAUs and dry coils; PCW cools tools, pumps and RF generators.

EquipmentLevelPoints worth watchingNotes
Large centrifugal chillerCoreCHW supply temp · CHW return temp · Load · Power draw · Efficiency (kW/ton) · FaultThousand-ton centrifugals (Trane, York, Carrier, Daikin) on BACnet/IP, typically N+1.
Cooling tower cellCoreTower leaving water · Tower entering water · Fan speed · Basin level · Water conductivity · Fan vibration
PumpCoreRunning · Speed · Differential pressureChilled and condenser water pumps; drives usually on Modbus TCP.
Process cooling water loopCoreSupply temp · Return temp · Supply pressure · Supply-return differential · Loop flow · Loop conductivity · Leak detected
Heat-recovery chiller / heat pumpOptionalHot water supply temp · Chilled water supply temp (recovery side) · Power draw · Combined COPHeat recovery displacing boiler gas — one of the main decarbonization levers.
Hot-water boilerCommonHot water supply temp · Firing rate · FaultHot water for MAU preheat and reheat.
Plate heat exchangerCommonSecondary supply temp · Approach · Primary pressure drop
Pressurization / expansion unitCommonSystem pressure · Low pressure alarm · Make-up today
Cooling tower chemical treatmentCommonConductivity · Chemical drum low
Side-stream filterOptionalFilter differential pressure

Cleanroom air

Make-up air, recirculation and FFUs hold cleanliness, the pressure cascade and temperature/humidity.

EquipmentLevelPoints worth watchingNotes
Make-up air unitCoreSupply air temp · Supply dew point · Outdoor airflow · Fan speed · Final filter pressure drop · FaultDew-point control sets cleanroom humidity.
Recirculation air unitCoreSupply air temp · Return air temp · Recirculation airflow · Dry-coil valve · Filter pressure drop
Fan-filter unit bankCoreFFUs running · FFUs in fault · Average speed · Bank power · FFU network faultGroup by feeder or control segment; clustered failures usually mean a circuit.
Cleanroom zoneCorePressure vs adjacent · Room temp · Relative humidity · Downflow velocity · Target class (ISO 14644-1) · Door held openTypical cascade 0.02–0.06 inWC (5–15 Pa).
Particle counterCoreParticles ≥ 0.1 µm · Particles ≥ 0.3 µm · Particles ≥ 0.5 µm · Particles ≥ 5.0 µm · Measured class (ISO equivalent) · Above target ISO classISO 14644-1 limits are per m³; divide by 35.3147 for per ft³.
Cleanroom FMCS summaryCommonWorst zone particles ≥ 0.5 µm · FFUs in fault (all banks) · Zones out of spec
HumidifierCommonControlled humidity · Cylinder / nozzle service
Pass-through / airlock interlockCommonBoth doors open · UV lamp hours
Airborne molecular contamination monitorCommonAcids · Bases (NH₃)
Fab micro-vibration monitorOptionalVC criterion met · Above tool spec

Process utilities: CDA, vacuum, bulk & specialty gas

The tools' lifeblood: lose supply and they stop; a leak is a life-safety matter.

EquipmentLevelPoints worth watchingNotes
Clean dry air compressorCoreDischarge pressure · Output · Load · Power draw · Surge detected · Fault
Desiccant air dryerCorePressure dew point · Pressure drop · Regeneration temp · FaultTypical pressure dew point −94°F (−70°C).
CDA headerCoreHeader pressure · Header dew point · Demand
Bulk gas supplyCoreTank level · Supply pressure · Vaporizer outlet temp · Flow · Impurity · Reserve supply in useN2, O2, Ar, H2, CO2; tank telemetry is usually the gas supplier's.
On-site nitrogen generatorOptionalProduct O2 content · Output · Outlet pressure · Off-purity (on LIN backup)
Specialty gas cabinetCoreCylinder pressure · Delivery pressure · Cylinder weight (scale) · Cabinet exhaust · Excess-flow trip · Auto-shutoff valve closed · Low cabinet exhaustToxic, flammable and corrosive gases live in exhausted cabinets (IFC HPM provisions).
Valve manifold boxCoreDistribution pressure · Sticks open · Enclosure exhaust · Enclosure gas detected · Auto-shutoff valve closed
Specialty gas usage meterCommonCurrent use · Used today (scf) · Days of supply left
Process vacuum pumpCoreInlet pressure · Motor power · N2 purge flow · Pump body temp · Service warningEbara, Edwards and Kashiyama dry pumps, typically Modbus or Profinet.
House vacuum systemCommonVacuum · Pumps running
Bulk chemical delivery systemCoreSupply tank level · Supply pressure · Supply flow · Drip-pan leak · Double-containment leak · Auto-shutoff valve closedAcids, bases and solvents in double-contained piping.
CMP slurry supplyCoreDay tank level · Loop supply pressure · Loop flow · Large particles ≥ 1 µm (per mL) · Drip-pan leak
Chemical dilution unitCommonOutlet concentration · Leak · Concentration alarm
Nitrogen purifierCommonOutlet O₂
Tank farm levelCommonLevel · High-high level · Bund leak
Cryogenic vaporizerCommonOutlet gas temp · Low outlet temp

UPW, reclaim & wastewater

UPW quality hits yield directly; wastewater must meet the discharge permit.

EquipmentLevelPoints worth watchingNotes
Reverse osmosis unitCorePermeate conductivity · Permeate flow · Recovery · Membrane differential
Electrodeionization unitCoreProduct resistivity · Product flow
UV TOC reducerCoreUV intensity · Outlet TOC
UPW polishing loopCoreSupply resistivity · TOC · Dissolved oxygen · Dissolved silica · Particles ≥ 0.05 µm (per mL) · Supply flow · Supply pressureTypical targets: 18.2 MΩ·cm and TOC < 1 ppb (tighter at leading-edge nodes).
Water reclaim systemCommonReclaim flow · Reclaim rate · Reclaim conductivity · Reclaim TOC · Diverted to drain (off-spec)
pH neutralization systemCoreEffluent pH · Influent pH · Caustic dosing · Acid dosing · Flow
Fluoride wastewater treatmentCoreEffluent fluoride · Reactor pH · Clarifier turbidity
Final effluent monitorCoreDischarge flow · Discharge pH · COD · Fluoride · Discharge temp
Lift stationCommonWet-well level · Pumps running · High level
Domestic water boosterCommonDischarge pressure · Flow
Water tank / reservoir levelCommonLevel · Low level · Overflow level
Resistivity analyzerCommonResistivity

Exhaust & abatement

Tool exhaust must never fail; abatement keeps the air permit.

EquipmentLevelPoints worth watchingNotes
Process exhaust systemCoreExhaust main static · Exhaust airflow · Fans running · Low exhaust staticWatch general, heat, solvent and acid exhaust separately; N+1 fans.
Acid exhaust scrubberCoreRecirculation pH · Recirculation flow · Packing pressure drop · Inlet duct static · Low recirculation flow
Alkaline exhaust scrubberCommonRecirculation pH · Recirculation flow · Packing pressure drop
VOC concentratorCoreInlet VOC · Outlet VOC · Removal efficiency · Desorption temp
Regenerative thermal oxidizerCommonCombustion chamber temp · Inlet solvent (LEL) · Bypass damper open
Point-of-use abatementCoreCombustion / reaction temp · Inlet pressure · Bypassed (untreated) · Service warningPoint-of-use treatment for PFCs, silane, arsine and the like.

Power & sub-metering

One voltage sag can drop a whole bay of tools.

EquipmentLevelPoints worth watchingNotes
Medium-voltage switchgearCoreBus voltage · Incoming current · Real power · Breaker closed · Protective trip · Relay troubleMonitor only — never operate breakers.
Low-voltage switchgearCoreBus voltage · Load current · Real power · Power factor · Current THD · Breaker trip
Power transformerCoreTop-oil temp · Winding temp · Load · Gas / sudden-pressure alarm · Over-temperature alarm
UPSCoreLoad · Battery runtime · On bypassSNMP v3 (UPS-MIB).
UPS battery string monitorCoreString voltage · Lowest jar voltage · Highest jar voltage · Highest jar internal resistance · Highest jar temp · State of chargePer-jar resistance trending (one of the maintenance practices in IEEE 1188).
GeneratorCommonRunning · Output power · Fuel tank level · Starting battery voltage · Not in AUTO
Power quality meterCommonVoltage THD · Current THD · Voltage sags today · Sag / interruption eventVoltage sags are a common hidden cause of trips.
Site utility meterCoreSite power · Site power (MW) · Energy today · Power factor
Area energy meterCoreArea power · Energy today · 15-min demand · Power factorSub-metering by workshop or system for energy analysis and cost allocation.
Natural gas meterCommonNatural gas flow · Heat input (1,037 BTU/scf) · Gas today (scf)Natural gas in scfh, converted to BTU/h by heating value.
Static transfer switchCoreOn alternate source · Sources out of sync
Battery cell monitoringCommonHighest cell resistance · Cell alarm
-48 V DC power plantCommonDC bus voltage · AC input lost
Insulation monitoring device (IT system)CommonInsulation resistance · Insulation alarm
Busway / cable temperature (DTS)OptionalHottest point
Active harmonic filter (APF)CommonAfter current THD · Unit load · Modules in fault · Fan fault
Passive (tuned) harmonic filterCommonAfter current THD · Capacitor current, measured / rated · Resonance alarm
Automatic capacitor bankCommonPower factor · Capacitor current, measured / rated · Resonance alarm · Switching operations today
Dynamic voltage restorer (DVR)OptionalSags corrected today · On bypass
Power conditionerCommonOutput voltage · Transformer temp
EMI filterOptionalLeakage current
Transformer DGA monitorCommonHydrogen · Acetylene
Bushing monitorOptionalPower factor (tan δ) · Capacitance change
Winding temperature monitorCommonWinding hot spot
On-load tap changer control (OLTC)OptionalTap position · Tap fault · Operations today
Partial discharge monitorCommonDischarge magnitude
Switchgear wireless temperatureCommonHottest point · Phase difference
Arc-flash protection relayCommonArc trip · Protection not ready
Neutral grounding resistor monitorOptionalNGR resistance · Resistor open · Ground fault
Surge arrester monitorOptionalTotal leakage · Resistive current
Flywheel / rotary UPSOptionalFlywheel speed · Discharging · Bearing temp
Tool PDU / EMOCommonEMO pressed

Life safety: gas monitoring, fire, leaks Monitor only

Two-stage alarms set from TLVs; everything monitor-only.

EquipmentLevelPoints worth watchingNotes
Gas monitoring systemCoreActive alarms · Active faults · Auto-shutoff activated · Evacuation alarmThe GMS performs the shut-off interlocks; the platform only monitors.
Silane detectorCoreSilane (SiH4) · Alarm 1 (low) · Alarm 2 (high)TLV 5 ppm.
Ammonia detectorCoreAmmonia level · Ammonia alarmTLV 25 ppm.
Chlorine detectorCoreChlorine (Cl2) · Alarm 1 (low) · Alarm 2 (high)TLV 0.5 ppm.
HF detectorCoreHydrogen fluoride (HF) · Alarm 1 (low) · Alarm 2 (high)TLV-C 2 ppm.
Arsine detectorCommonArsine (AsH3) · Alarm 1 (low) · Alarm 2 (high)TLV 5 ppb; implant and III-V epitaxy.
Phosphine detectorCommonPhosphine (PH3) · Alarm 1 (low) · Alarm 2 (high)TLV 50 ppb.
NF3 detectorCommonNitrogen trifluoride (NF3) · Alarm 1 (low) · Alarm 2 (high)Chamber-clean gas; TLV 10 ppm.
Hydrogen detectorCoreHydrogen (% LEL) · Alarm 1 (low) · Alarm 2 (high)
Oxygen deficiency monitorCoreOxygen · Alarm 1 (O2 below 19.5 %) · Alarm 2 (O2 below 18 %)Nitrogen and inert-gas areas: 19.5 % and 18 % stages.
Fire alarm zone & linkageCoreFire alarm · Supervisory · Trouble · Linkage: air handlers stopped · Linkage: fire/smoke dampers closed · Linkage: smoke exhaust running · Linkage: elevators recalledLinkage proofs verify the fire system did what it should.
Fire alarm panelCoreFire alarm · Supervisory signal · Trouble signalMonitor only (NFPA 72).
Aspirating smoke detectorCommonSmoke obscuration (%/ft) · Alert · Action · Fire 1 · Airflow fault
Leak detection cableCoreLeak detected · Distance to leak · Leak zone · Cable break or contamination
Smoke exhaust fanCommonRunning · Damper not provenSmoke exhaust or stair pressurization fans; monitor only.
Fire / smoke damperCoreClosed · Position fault · Days since test
Clean-agent suppression panelCoreDischarged · Cylinder pressure low

Security & video Monitor only

Camera and door status, and video linkage: cameras are linked to areas, devices and alarm rules; on an alarm the gateway takes an ONVIF snapshot and attaches it to the alarm, with a live-view link to the NVR/VMS. Core never contacts a camera.

EquipmentLevelPoints worth watchingNotes
Video cameraCommonOnline · Recording · Motion detected · Video analytics alarm · Tamper (blocked or moved)Status via the VMS (Milestone, Genetec…); on an alarm the gateway takes an ONVIF snapshot and attaches it to the alarm — Core never contacts a camera.
Access-controlled doorCommonDoor open · Door held open · Door forcedDoor events can drive camera linkage.
Perimeter intrusion detectionCommonPerimeter alarm
Network switch (SNMP)CommonPorts down · PSU fault

Life-safety equipment (fire alarm, gas detection, emergency power transfer) and protection devices are monitored only. FacilityOS never sends them commands.

Standards and compliance

Standards and complianceNotes
ISO 14644-1Cleanroom classification by airborne particle concentration; fabs typically run ISO 3–5 in front-end and ISO 6–7 in packaging.
ISO 14644-2Monitoring to provide evidence that a cleanroom keeps its class.
SEMI S2EHS guideline for semiconductor manufacturing equipment.
SEMI F63Guide for ultrapure water used in semiconductor processing (typical values on the order of 18.2 MΩ·cm and TOC < 1 ppb).
NFPA 318Standard for the protection of semiconductor fabrication facilities.
International Fire Code (HPM)IFC provisions for hazardous production material (HPM) facilities: gas cabinets, exhaust, gas detection and emergency power.
NFPA 55Compressed Gases and Cryogenic Fluids Code (bulk tanks, cylinder storage).
CGA G-13Storage and handling of silane and silane mixtures.
ACGIH TLVsThreshold limit values for airborne chemicals, commonly used to set gas-detector alarm levels.
NFPA 72National Fire Alarm and Signaling Code.
IEC 62443Security for industrial automation and control systems.
ANSI/ISA-18.2Management of alarm systems for the process industries.

Standards are listed with what they cover; numeric values are typical figures, not requirements for every site. FacilityOS supports your compliance work; it does not certify a site.

Segments of Semiconductor & IC manufacturing

Full Semiconductor & IC manufacturing solution →

How we deliver

We can take a Semiconductor & IC manufacturing project from survey and design through procurement, installation, commissioning and training — all of it, or only the stages you need.

  1. Site survey & needs assessment
  2. Solution design
  3. Procurement
  4. Installation
  5. Commissioning & acceptance
  6. Training
  7. Go-live & support

See it with your own equipment

Open the live demo now, or tell us about your site and we will map your equipment and systems to FacilityOS.