Battery module / pack — New-energy manufacturing

Cell sorting, laser welding and end-of-line testing.

Battery module / pack is a segment of New-energy manufacturing. Below are the systems and equipment FacilityOS covers for it, filtered from the New-energy manufacturing solution.

How FacilityOS helps

Systems and equipment

Core: every site of this kind has it. Common: most sites have it. Optional: depends on the site.

Chiller plant & process cooling

Dry-room pre-cooling and formation heat are the largest cooling loads.

EquipmentLevelPoints worth watchingNotes
Large centrifugal chillerCoreCHW supply temp · CHW return temp · Load · Power draw · Efficiency (kW/ton) · FaultThousand-ton centrifugals (Trane, York, Carrier, Daikin) on BACnet/IP, typically N+1.
Cooling tower cellCoreTower leaving water · Tower entering water · Fan speed · Basin level · Water conductivity · Fan vibration
PumpCoreRunning · Speed · Differential pressureChilled and condenser water pumps; drives usually on Modbus TCP.
Process cooling water loopCoreSupply temp · Return temp · Supply pressure · Supply-return differential · Loop flow · Loop conductivity · Leak detected
Heat-recovery chiller / heat pumpOptionalHot water supply temp · Chilled water supply temp (recovery side) · Power draw · Combined COPHeat recovery displacing boiler gas — one of the main decarbonization levers.
Process chillerCommonProcess water supply temp · Process water return temp · Load
Dry cooler / adiabatic coolerCommonLeaving fluid temp

Dry rooms & clean areas

Moisture reacts with electrolyte to make HF; dry-room dew point is the lifeline of cell quality.

EquipmentLevelPoints worth watchingNotes
Air handlerCommonSupply air temp · Duct static pressure

Process: coating, formation, lamination, test

Monitor process equipment's utility and safety status.

EquipmentLevelPoints worth watchingNotes
End-of-line testerCoreTested today · First-pass yield · Test cycle time
Robotic weld cellCommonWeld current · Parts today · Safety guard trippedLaser or ultrasonic weld cells.
Line controller (OEE)CommonOEE · Output (parts/h) · Energy per part
Thermal oil heaterCommonOutlet oil temp · Low-flow trip

Solvent recovery & abatement

NMP recovery saves cost and keeps the air permit.

EquipmentLevelPoints worth watchingNotes
Process exhaust systemCoreExhaust main static · Exhaust airflow · Fans running · Low exhaust staticWatch general, heat, solvent and acid exhaust separately; N+1 fans.
Dust collectorCommonFilter pressure drop · Spark detectedElectrode powder and laser-weld fume; mind combustible dust.

CDA, nitrogen & hydrogen

Dry rooms need very dry CDA; nitrogen inerts and shields welds.

EquipmentLevelPoints worth watchingNotes
Air compressorCoreDischarge pressure · Load · Power draw · Fault
Desiccant air dryerCorePressure dew point · Pressure drop · Regeneration temp · FaultTypical pressure dew point −94°F (−70°C).
CDA headerCoreHeader pressure · Header dew point · Demand
Bulk gas supplyCoreTank level · Supply pressure · Vaporizer outlet temp · Flow · Impurity · Reserve supply in useN2, O2, Ar, H2, CO2; tank telemetry is usually the gas supplier's.
On-site nitrogen generatorOptionalProduct O2 content · Output · Outlet pressure · Off-purity (on LIN backup)
Cryogenic vaporizerCommonOutlet gas temp · Low outlet temp

Water & wastewater

PV and hydrogen need pure water; coating and cleaning make wastewater.

EquipmentLevelPoints worth watchingNotes
Final effluent monitorCommonDischarge flow · Discharge pH · COD
Domestic water boosterCommonDischarge pressure · Flow

Power, storage & sub-metering

Formation is the largest electrical load; on-site storage and PV shave peaks.

EquipmentLevelPoints worth watchingNotes
Medium-voltage switchgearCoreBus voltage · Incoming current · Real power · Breaker closed · Protective trip · Relay troubleMonitor only — never operate breakers.
Low-voltage switchgearCoreBus voltage · Load current · Real power · Power factor · Current THD · Breaker trip
Power transformerCoreTop-oil temp · Winding temp · Load · Gas / sudden-pressure alarm · Over-temperature alarm
UPSCoreLoad · Battery runtime · On bypassSNMP v3 (UPS-MIB).
UPS battery string monitorCoreString voltage · Lowest jar voltage · Highest jar voltage · Highest jar internal resistance · Highest jar temp · State of chargePer-jar resistance trending (one of the maintenance practices in IEEE 1188).
GeneratorCommonRunning · Output power · Fuel tank level · Starting battery voltage · Not in AUTO
Power quality meterCommonVoltage THD · Current THD · Voltage sags today · Sag / interruption eventVoltage sags are a common hidden cause of trips.
Site utility meterCoreSite power · Site power (MW) · Energy today · Power factor
Area energy meterCoreArea power · Energy today · 15-min demand · Power factorSub-metering by workshop or system for energy analysis and cost allocation.
Natural gas meterCommonNatural gas flow · Heat input (1,037 BTU/scf) · Gas today (scf)Natural gas in scfh, converted to BTU/h by heating value.
Rooftop solar inverterOptionalSolar output · Energy today
Motor control centerCommonMCC load · Current · Power factor · Current THD
Ring main unitCommonSF6 low · Fault passage indicator
Insulation monitoring device (IT system)CommonInsulation resistance · Insulation alarm
Microgrid controllerOptionalGrid exchange · Islanded
Wind turbineOptionalOutput · Fault
Static var generator (SVG / STATCOM)CommonPF after · Unit load · Modules in fault
Dynamic voltage restorer (DVR)OptionalSags corrected today · On bypass
Step voltage regulatorOptionalTap position · At tap limit
Transformer DGA monitorCommonHydrogen · Acetylene
On-load tap changer control (OLTC)OptionalTap position · Tap fault · Operations today
Surge arrester monitorOptionalTotal leakage · Resistive current
Surge protective device (SPD) statusCommonSPD failed · Backup breaker open
Weather stationCommonOutdoor temp · Wind speed

Thermal runaway, gas & fire Monitor only

Cell venting is the earliest warning of runaway, leaving only minutes to react.

EquipmentLevelPoints worth watchingNotes
Thermal runaway detectorCoreElectrolyte off-gas · Hydrogen · Hottest spot (IR) · Stage 1: off-gas detected · Stage 2: thermal runawayRequired in formation, aging stores and ESS areas.
Oxygen deficiency monitorCoreOxygen · Alarm 1 (O2 below 19.5 %) · Alarm 2 (O2 below 18 %)Nitrogen and inert-gas areas: 19.5 % and 18 % stages.
Fire alarm zone & linkageCoreFire alarm · Supervisory · Trouble · Linkage: air handlers stopped · Linkage: fire/smoke dampers closed · Linkage: smoke exhaust running · Linkage: elevators recalledLinkage proofs verify the fire system did what it should.
Fire alarm panelCoreFire alarm · Supervisory signal · Trouble signalMonitor only (NFPA 72).
Aspirating smoke detectorCommonSmoke obscuration (%/ft) · Alert · Action · Fire 1 · Airflow fault
Fire pumpCommonRunning · System pressure · Power phase failure
Sprinkler riserCommonRiser pressure · Waterflow alarm · Valve tamper
Leak detection cableCoreLeak detected · Distance to leak · Leak zone · Cable break or contamination
Smoke exhaust fanCommonRunning · Damper not provenSmoke exhaust or stair pressurization fans; monitor only.
Water mist systemOptionalPump unit not ready · Released

Security & video Monitor only

Camera and door status, and video linkage: cameras are linked to areas, devices and alarm rules; on an alarm the gateway takes an ONVIF snapshot and attaches it to the alarm, with a live-view link to the NVR/VMS. Core never contacts a camera.

EquipmentLevelPoints worth watchingNotes
Video cameraCommonOnline · Recording · Motion detected · Video analytics alarm · Tamper (blocked or moved)Status via the VMS (Milestone, Genetec…); on an alarm the gateway takes an ONVIF snapshot and attaches it to the alarm — Core never contacts a camera.
Access-controlled doorCommonDoor open · Door held open · Door forcedDoor events can drive camera linkage.
Perimeter intrusion detectionCommonPerimeter alarm

Life-safety equipment (fire alarm, gas detection, emergency power transfer) and protection devices are monitored only. FacilityOS never sends them commands.

Standards and compliance

Standards and complianceNotes
NFPA 855Installation of stationary energy storage systems, including spacing, detection and ventilation for Li-ion.
UL 9540Safety of energy storage systems and equipment.
UL 9540ATest method for evaluating thermal-runaway fire propagation in battery energy storage systems.
UL 1973Batteries for stationary and motive auxiliary power applications.
NFPA 86Standard for ovens and furnaces (flammable-vapor control in solvent ovens).
UN 38.3Transport testing for lithium batteries.
IEC 61215 / IEC 61730PV module design qualification and safety qualification.
NFPA 2Hydrogen Technologies Code.
EPA TSCA (NMP)US EPA risk evaluation and risk management of NMP under TSCA.
NFPA 72National Fire Alarm and Signaling Code.
IEC 62443Industrial automation and control system security.

Standards are listed with what they cover; numeric values are typical figures, not requirements for every site. FacilityOS supports your compliance work; it does not certify a site.

Segments of New-energy manufacturing

Full New-energy manufacturing solution →

How we deliver

We can take a New-energy manufacturing project from survey and design through procurement, installation, commissioning and training — all of it, or only the stages you need.

  1. Site survey & needs assessment
  2. Solution design
  3. Procurement
  4. Installation
  5. Commissioning & acceptance
  6. Training
  7. Go-live & support

See it with your own equipment

Open the live demo now, or tell us about your site and we will map your equipment and systems to FacilityOS.